BRUNNER Control Loading System
CLS Setup Guide
Configuration reference for BRUNNER force feedback devices: homing, force profiles, the force control loop, synchronisation, PDO communication and CAN bus wiring.
index.subindex in hexadecimal.BRUNNER Elektronik AG
As a modern, family-owned technology company we are a trusted and reliable partner to numerous companies across various industries and markets since 1968.
Our ability to handle all corporate core processes, from development to production and customer support, fully in-house creates sustainable advantages for our customers and partners: short response times, high flexibility and an integral understanding of quality. Our engaged and highly qualified employees share our enthusiasm for working for our customers, take over responsibility and live the values of team spirit and fairness.
With convincing solutions in the field of electronics, intelligent drives and innovative simulation products and components we address customers in markets like mechanical engineering, packaging industry, process engineering, medical technology, robotics and simulation-based training.
Control Loading Systems since 2009
We developed a portfolio of leading Control Loading Systems in close cooperation with experienced pilots and experts from the flight training industry. Our extensive experience with modern Drive and Control technologies and our passion for aviation has been the foundation and driving force behind our product development initiative.
All our CLS devices provide realistic force feedback using advanced control technology, feature adjustable positions and angles, and are compatible with a wide range of simulation software and platforms. They offer a highly realistic and immersive training experience, making them an excellent choice for professional pilots, flight simulator enthusiasts, and other industries that require realistic control feedback.
1About this guide
Control loading systems are complex devices. They work out of the box, but professional and certified simulators often need adjustments: a reduced range of motion, different forces, more or less damping, or two synchronised seats. This guide explains the functions behind those settings and the CANopen objects that control them.
The main subject is the Force Feedback Mode (0x6060 = −1), in which all BRUNNER CLS devices run. Settings are usually made with Simux, CLS2Sim or the CANopen Commander.
How to read object references
| Notation | Meaning |
|---|---|
| 0x2114.0 | Object index 0x2114, subindex 0 |
| 0x2101.1 bit 13 | Single bit in a bit-field object, counted from bit 0 (least significant) |
| 0x2100.E | Subindex in hexadecimal: E = 14, 10 = 16 |
| RW RO | Read/write or read-only |
| Factory | Preset at the factory. Changing it needs factory access; contact BRUNNER. |
Support, training and contact
Technical support
E-mail support@brunner-innovation.swiss or open a ticket in the Helpdesk. Remote support by TeamViewer is available on an hourly basis and recommended for complex systems and first installations.
Sales, training, support hours
sales@brunner-innovation.swiss
Training at your site or at BRUNNER in Hittnau.
BRUNNER Elektronik AG
Industriestrasse 27
8335 Hittnau, Switzerland
+41 44 953 10 10
info@brunner-innovation.swiss
www.brunner-innovation.swiss
2Operating modes
BRUNNER CLS devices communicate over CANopen. The stack follows CiA 301 (communication profile) and CiA 402 (drives and motion control). BRUNNER is a member of CAN in Automation.
The operating mode is selected with 0x6060 Modes of Operation. The device selects the Force Feedback Mode automatically at start-up.
| 0x6060 | Mode | Status on CLS devices |
|---|---|---|
| −1 | Force Feedback Mode (BRUNNER specific) | Active, selected automatically |
| 1 | Profile Position Mode | Disabled |
| 3 | Profile Velocity Mode | Disabled |
| 4 | Profile Torque Mode | Disabled |
| 6 | Homing Mode | Not used directly — homing runs inside the Force Feedback Mode, see 3 |
| 7 | Interpolated Position Mode | Disabled |
| 8 – 10 | Cyclic Synchronous Position / Velocity / Torque Mode | Disabled |
3Homing and limits
A CLS axis with an incremental position sensor does not know where it is when it is switched on. Homing finds a known reference, sets the position counter and then hands over to force feedback. Until homing is finished, no force feedback mode is active.
Homing ends as soon as the reference is set. The axis does not drive to the centre as part of homing: once force feedback is active, the spring effect (Move Back) returns it to zero.
3.1Ranges and reference points
Three ranges are nested inside each other. The software limits are normally set to the hardware limits and are reduced only when the simulator needs a smaller range of motion.
Devices with limit switches or an absolute position sensor (for example the Direct Drive solution) do not have to travel to a mechanical stop to reference themselves.
3.2When homing runs
By default a device homes once after power-up. Four settings decide when that happens:
| Object | Name | Effect |
|---|---|---|
| 0x2101.1 bit 10 | Auto State | 1 = after power-up the axis enables itself and homes once, without a command from the controller. |
| 0x2101.1 bit 13 | Start Homing | 1 = homing starts as soon as the drive is in Operation Enabled. |
| 0x2101.1 bit 14 | No Init | 1 = homing is skipped; the axis reports "initialised" after Operation Enabled. Position is not referenced. |
| 0x2100.E bit 1 | Init Always | 1 = homing runs again on every 0 → 1 change of Start Homing. With 0 the device homes only once per power cycle. |
3.3Homing methods: interactive demonstration
The homing method is set in 0x6098 Homing Method. Choose a method to watch the movement. You can also inject a fault to see how the device reacts and which error code it reports in 0x2059.
Homing simulator
Schematic axis. Positions and times are illustrative, not device values.
3.4The methods in detail
Methods −1 to −4 are BRUNNER specific and reference on a mechanical stop by detecting the rise in motor current. Methods 17, 18 and 35 follow CiA 402. Method 0 does not move.
3.5Homing parameters
| Object | Name | Unit | Description | Used by |
|---|---|---|---|---|
| 0x6098.0 | Homing Method | — | −4 … −1, 0, 17, 18, 35. See 3.4. Factory | all |
| 0x6099.1 | Homing Speed | rpm (motor) | Motor speed while searching the stop or switch. | −4 … −1, 17, 18 |
| 0x2058.0 | Homing Current Limit | mA | Current at which a mechanical obstacle is detected. For −4 … −1 this is the stop detection; for 17/18 exceeding it is an error. | −4 … −1, 17, 18 |
| 0x2057.0 | Homing Delay | ms | Time the current must stay above the limit before the stop is accepted as reference. | −4 … −1 |
| 0x205A.1 | Homing Option | — | 0 = standard homing; 1 = new homing, the real (measured) position is used for the calculation. | −4 … −1 |
| 0x205A.2 | Homing Option KP | — | Separate proportional gain of the regulator during homing. | moving methods |
| 0x607C.0 | Home Offset | increments | Offset of the centre position. For −4 … −1 the centre is calculated from the hardware limit; for 0 and 35 it is added to the current position. | all |
| 0x607D.1 / .2 | Min / Max Position Limit | increments | Hardware limits, just inside the mechanical stops (distance differs per unit). Methods −3/−4 drive to the opposite limit to check the range. | −4 … −1 |
3.6Status and error codes
| Object | Name | Description |
|---|---|---|
| 0x6041 bit 12 | Homing attained RO | 1 = homing completed successfully. |
| 0x6041 bit 13 | Homing error RO | 1 = homing failed. Read 0x2059 for the reason. |
| 0x2059.0 | Last Homing Error RO | Error code of the last failed homing, see table below. |
| 0x2059 | Error | Methods | Typical cause and remedy |
|---|---|---|---|
| 1 | Current too high | 17, 18 | The axis hit an obstacle before reaching the limit switch. Remove the obstacle, check the linkage for binding. |
| 2 | Positive limit switch active | 17, 18 | The positive limit switch is active when it should not be, e.g. already at start. Check switch and wiring. Does not occur with the stop methods −1 … −4. |
| 3 | Negative limit switch active | 17, 18 | As error 2 for the negative limit switch. |
| 4 | Position check failed | −3, −4 | The axis met resistance before reaching the opposite hardware limit. Usually an obstacle was taken for the stop during the first search, or the mechanics changed. Check for obstacles and loose parts. |
| 5 | Force sensor out of range | all | Force sensor value invalid during initialisation. Do not touch the control during start-up. Run a sensor offset (0x2101.1 bit 11). |
| 10 | Homing timeout | all moving | Reference not found in time. Check homing speed, mechanics and limit switch wiring. |
3.7Position limits
| Object | Name | Description |
|---|---|---|
| 0x209C.0 | Software negative limit RW | Lower end of the moving range. |
| 0x2119.0 | Software positive limit RW | Upper end of the moving range. Software limits cannot exceed the hardware limits. |
| 0x2100.8 | Soft Limit Stop Ramp RW | Stiffness beyond a software limit: the drive adds a force that grows with the distance beyond the limit (limited to 0x7FFF and 0x6072). Lower value = harder stop, 1 = hardest stop. |
| 0x2100.C | Select Profile Mode RW | 0 = symmetric: negative limit = −0x21191 = asymmetric, same slope: negative limit 0x209C2 = asymmetric, curve scaled to each limit: negative limit 0x209CIn modes 1/2 the negative limit is at most −300. Effect on the force curve: 4.2. |
| 0x2100.E bit 2 | Disable Limits RW | 1 = software limits off. Dangerous, see warning. |
Outside a software limit the force curve is evaluated with scale factor 100 % and the stiffening force from 0x2100.8 is added, so the stop feels like a hard spring rather than a wall.
3.8Troubleshooting homing
| Symptom | Check |
|---|---|
| Axis does not move after power-up | Auto State (0x2101.1 bit 10) off and no Start Homing from the controller; or No Init (bit 14) set; or the device already homed and Init Always is 0. |
| Centre is offset after every start | Something limits the travel before the real stop (cable, cockpit panel). Methods −1/−2 accept any obstacle as the stop; −3/−4 detect it with error 4. |
| Homing error 5 at start-up | Hands on the control during start-up, or sensor drift. Enable the sensor offset at power-up (bit 11). |
| Homing error 10 | Speed too low, heavy friction, or the limit switch never triggers (wiring). |
4Force feedback modes
Inside the Force Feedback Mode the device runs one of four FF modes. All of them need a completed homing. By default FF mode 1 or 2 is active with a force profile that suits the device.
4.1Overview and selection
| FF mode | Use | Force comes from | Selected by |
|---|---|---|---|
| 1 Profile Force | Stick, yoke, rudder: force rises with deflection | Force curve: 9 points 0x2113 (18 in the extended layout), scaled by 0x2114 | 0x2101.1 bit 2 = 1 |
| 2 Friction Force | Collective, throttle: constant friction over the full range | 0x6071 Target Torque | bit 2 = 0 and not FF mode 3 |
| 3 Constant Force | Own force models in an external real-time controller | 0x6071 Target Torque, signed | bit 1 = 1, bit 0 = 0, bit 2 = 0 |
| 4 DirectX | Games with DirectInput force feedback over USB | The game, through Windows | 0x2180.1 = 1 |
Bits of 0x2101.1. Profile Force has priority: Constant Force only becomes active when Move Back (bit 0) and Run Profile Mode (bit 2) are both off.
| Bit 2 Run Profile | Bit 1 Constant Force | Bit 0 Move Back | Active FF mode |
|---|---|---|---|
| 1 | any | any | 1 Profile Force |
| 0 | 1 | 0 | 3 Constant Force |
| 0 | 0 | any | 2 Friction Force |
| 0 | 1 | 1 | 2 Friction Force with move back |
4.2Profile Force Mode (FF mode 1): the force curve
In this mode the drive behaves like a spring with a programmable characteristic. The force curve gives, for every stick position, the force the pilot has to apply before the stick moves. This force is the virtual force 0x2093. The curve is used when 0x2101.1 bit 2 = 1; with bit 2 = 0 the virtual force is the constant 0x6071 over the whole range (Friction Force Mode).
How the control loop uses the curve
Every 400 µs (2.5 kHz) the drive:
- reads the position:
0x6064+ trim position (with the autopilot active:0x6064only); - looks up the virtual force on the force curve;
- adds the friction (friction profile
0x20A2/0x20A3or constant friction0x211D.B) and, outside the software limits, the soft-limit force; - compares the result with the measured force;
- if the pilot pushes harder than that, moves with a speed proportional to the excess force (see 5.9).
Forces are in the units of the force sensor selected by 0x2107, positions in increments of 0x6064. The sign of the position (after trim) decides which side of the curve is used. With trim the zero point of the curve moves to −trim.
Calculated with the firmware formula (integer arithmetic). Positive limit 0x2119 = 5700, 0x211B = 30000. Drag a point to change it, or type values below. In the extended layout points also move sideways; while you drag, the position is shown under the axis. Outside the software limits the soft-limit force is added on top (not shown, not part of 0x2093).
Standard layout (symmetric, equidistant)
Used when 0x20A1.1 and 0x20A1.2 are both 0. Only the nine points 0x2113.1 – .9 count. Point n lies at (n − 1) × step: point 1 is the centre, point 9 is at 8 × step. Both sides use the same force values; only the step width can differ.
0x2100.C profile mode | Step for x ≥ 0 | Step for x < 0 |
|---|---|---|
| 0 symmetric | 0x2119 / 8 | 0x2119 / 8 |
| 1 asymmetric, same slope | max(0x2119, |0x209C|) / 8 | same as x ≥ 0 |
| 2 asymmetric, scaled | 0x2119 / 8 | |0x209C| / 8 |
Integer division; a step of 0 is replaced by 1. Between two points the force is interpolated linearly. Beyond point 9 the slope of the last segment (8 → 9) continues; the curve does not stay flat.
Extended layout (asymmetric, free positions)
Active as soon as 0x20A1.1 or 0x20A1.2 is greater than 0. Then all 18 points count:
| Side | Points | Positions | Forces |
|---|---|---|---|
| negative (x ≤ 0) | 1 – 9 | 0x20A1.1 – .9 | 0x2113.1 – .9 |
| positive (x > 0) | 10 – 18 | 0x20A1.A – .12 | 0x2113.A – .12 |
Positions are entered as positive, increasing distances from the centre. From the centre to the first point the force rises linearly from 0 to the first force; after the last point it stays constant. The profile mode does not change the curve in this layout, but it still sets the negative software limit.
Scale factor
Both end values of a segment are multiplied by the active scale factor S / 100 before interpolating. Exception in the standard layout: the centre value 0x2113.1 is scaled only when S < 100 %. A scale factor above 100 % does not raise the breakout force, only the rest of the curve.
The active scale factor is 0x2114. While the stick returns towards the centre it is 0x2171 Reverse Scale Factor, if that is above 19. It is 100 % while the drive is not in the FF run state and outside the software limits.
| Object | Name | Description |
|---|---|---|
| 0x2114.0 | Scale Factor RW | 20 – 1000 %, 100 = values as entered |
| 0x2171.0 | Reverse Scale Factor RW | Scale factor for the return movement, 0 – 1000 %; used only if > 19 |
| 0x211E.0 | Scale Factor Step RW | 0 = new value at once. > 0 = S moves by this value every 102 cycles (≈ 40.8 ms). Example: 5 takes 100 → 200 % in 20 steps ≈ 0.8 s. |
| 0x2100.F | One-sided scaling RW | −5 … 5, only if 0x211E = 0. p > 0: S × p / 100 on the positive side; p < 0: S × |p| / 100 on the negative side. |
Centre force and centre zone
0x6071 Target Torque (if ≥ 0) is the force at the centre and the minimum force of the whole curve: both segment end values are raised to at least 0x6071, and so is the result. It is not multiplied by the scale factor.
The width of the centre zone is W = 0x6067. The drive limits W to 0x2119 / 20 (at least 10), on yoke devices to at least 100, and writes the limited value back to 0x6067.
| |x| | Force |
|---|---|
| 0 … ¾ W | 0x6071, flat |
| ¾ W … W | linear from 0x6071 to the first curve value |
| W … 2 W | catch-up zone: the curve runs twice as fast and meets the normal curve at 2 W |
| > 2 W | normal curve |
With Move Back (0x2101.1 bit 0) active, the return force inside ±½ W falls linearly from 0x6071 to 0 at the centre, so the stick settles exactly on zero. The chart below shows all zones: use Centre zone to zoom in.
If 0x6071 < 0, the centre zone and the catch-up zone are off.
Fade-out at low scale factors
Below the scale factor 0x211F the force above 0x6071 is reduced linearly: F = (F − 0x6071) × (S − 19) / (0x211F − 19), then raised to at least 0x6071 again. At S = 19 the curve is flat at 0x6071. This simulates the slack controls at very low airspeed.
Limits
- The virtual force is limited to 80 % of
0x211BSensor Error. This limit is read once after power-up: a change of0x211Btakes effect only after a restart. - The result is stored in
0x2093Virtual Force. - Outside the software limits a stiffening force is added (not part of
0x2093) and the scale factor is 100 %. See 3.7.
Worked examples
Standard layout: 0x2100.C = 0, 0x2119 = 5700 (step 712), 0x2113.1 – .9 = 50, 60, 100, 120, 140, 160, 180, 220, 260, S = 100 %, 0x6071 = 20, 0x6067 = 30, 0x211F = 40.
| x | 0 | 20 | 25 | 30 | 60 | 100 | 712 | 1000 | 1424 | 5000 | 5696 | 7000 | −712 | −3000 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| F | 20 | 20 | 28 | 50 | 50 | 51 | 60 | 76 | 100 | 220 | 260 | 333 | 60 | 144 |
Up to 23 (¾ W) the force is 20. It reaches point 1 (50) at W = 30 and point 9 (260) at 8 steps = 5696. Beyond, the last slope continues (7000 → 333).
Extended layout: points 1 – 9 at 300, 800, 1500, 2200, 3000, 3800, 4500, 5100, 5700 with 40, 80, 150, 220, 300, 380, 450, 520, 600; points 10 – 18 at 400, 1000, 1800, 2600, 3400, 4200, 4800, 5300, 5700 with 60, 120, 200, 300, 400, 500, 600, 700, 800; S = 100 %, 0x6071 = 20, 0x6067 = 30.
| x | −6500 | −5700 | −3000 | −300 | −150 | 0 | 150 | 400 | 700 | 1000 | 3000 | 5700 | 6500 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| F | 600 | 600 | 300 | 40 | 30 | 20 | 35 | 60 | 90 | 120 | 350 | 800 | 800 |
Beyond the last point the force stays constant (600 / 800).
Objects
| Object | Name | Description |
|---|---|---|
| 0x2101.1 bit 2 | Force Linear Up (Run Profile Mode) RW | 1 = use the force curve; 0 = constant 0x6071 |
| 0x2101.1 bit 0 | Move Back RW | 1 = spring effect returns the axis to zero, see 5.8 |
| 0x2113.1 – .12 | Force Profile RW | U16, force values of the points (sensor units). Standard: .1 – .9; extended: .1 – .12 (18 points) |
| 0x20A1.1 – .12 | Force Profile Position RW | S32, positions of the points (increments), extended layout only. .1 or .2 > 0 switches to the extended layout. |
| 0x2100.C | Profile Mode RW | 0 symmetric, 1 asymmetric same slope, 2 asymmetric scaled. Also sets the negative software limit. |
| 0x2119.0 | Pos Limit RW | S32 ≥ 0, positive software limit; step width of the standard layout |
| 0x209C.0 | Neg Limit RW | S32 ≤ 0, negative software limit (profile mode 1/2) |
| 0x2114.0 | Scale Factor RW | 20 – 1000 % |
| 0x2171.0 | Reverse Scale Factor RW | 0 – 1000 %, during the return movement if > 19 |
| 0x211E.0 | Scale Factor Step RW | Ramp, see above |
| 0x2100.F | One-sided Scaling RW | −5 … 5 |
| 0x6071.0 | Target Torque RW | S16, centre force and minimum force |
| 0x6067.0 | Position Window RW | U32, width of the centre zone (limited by the drive). Also used by the autopilot. |
| 0x211F.0 | Manual Offset Off Pos RW | Scale factor below which the curve fades out |
| 0x211B.0 | Sensor Error RW | Virtual force limited to 80 % of it; restart after change |
| 0x2101.1 bit 15 | Invert Position Factory | Inverts the position direction |
| 0x2093.0 | Virtual Force RO | S32, result of the curve (without soft-limit force) |
| 0x20A2.1 – .12 | Friction Profile Position RW | Positions for the friction profile 0x20A3 |
| 0x20A3.1 – .12 | Friction Profile RW | Friction values at the positions in 0x20A2 |
| 0x211D.B | Constant Friction Value RW | Friction over the whole range, used instead of a friction profile |
| 0x2100.10 | Enable Detent Move Back RW | 1 = detents on. The detent is defined in the extended force curve, see below. |
0x2100.10 = 1, detents are defined in the extended force curve (0x20A1 / 0x2113). A detent needs at least three neighbouring points: the middle one has a lower force than its neighbours and marks the detent position. The dip can also consist of two lower points.0x20A2) and the friction values (0x20A3). As with the extended force curve, points 1 – 9 are the negative side and 10 – 18 the positive side; positions are distances from the centre. Between the points the friction is interpolated linearly; after the last point it stays constant. The profile is only used when the first position point 0x20A2.1 has a value; otherwise the constant friction 0x211D.B applies.0x2113.1 is not amplified by a scale factor above 100 %. End of curve: standard keeps the last slope, extended stays at the last value. Centre feel: 0x6071 sets the centre and minimum force, 0x6067 the width of the soft centre.4.3Friction Force Mode (FF mode 2)
For controls that need the same friction everywhere, such as a helicopter collective. The force curve is inactive: the virtual force is the constant 0x6071 Target Torque (≥ 0) over the whole range. Friction from the friction profile or 0x211D.B is added as in the other modes.
| Object | Name | Description |
|---|---|---|
| 0x2101.1 bit 2 | Run Profile Mode | 0 = Friction Force Mode |
| 0x6071.0 | Target Torque | Friction force, ≥ 0 |
| 0x2101.1 bit 0 | Move Back | Possible, but rarely useful in this mode |
4.4Constant Force Mode (FF mode 3)
Applies a constant force in one direction: 0x6071 Target Torque, positive or negative. The axis moves with that force until something holds it. An external controller can build its own force model by reading the position and writing the force continuously. This needs a fast, regular update rate; use the Fast Communication Mode. Delays in the loop are felt at the control.
| Object | Name | Description |
|---|---|---|
| 0x2101.1 bit 1 | Constant Force | 1 = Constant Force Mode, only if bit 0 and bit 2 are 0 |
| 0x6071.0 | Target Torque | Force, signed |
The spring effect is not active in this mode.
4.5DirectX Mode (FF mode 4)
Some devices support DirectX force feedback over USB. BRUNNER uses the standard Microsoft implementation, so no driver is needed: games that support DirectInput force feedback control the forces directly. Switch the mode with the USB Config Tool.
| Object | Name | Description |
|---|---|---|
| 0x2180.1 | Enable RW | 1 = DirectX mode. The device restarts after a change. |
| 0x2180.10 | Global Force Scale RW | Overall force scaling |
| 0x2180.12 | Spring Effect Gain RW | |
| 0x2180.13 | Global Device Damping RW | |
| 0x2180.14 | Periodic Effect Gain RW | |
| 0x2180.15 | Constant Force Effect Gain RW | |
| 0x2180.16 | Damper Effect Gain RW |
4.6FF control word 0x2101.1
Most mode settings are bits in one 16-bit object. The table collects all bits documented anywhere in this guide.
| Bit | Name | 1 means | See |
|---|---|---|---|
| 0 | Move Back | Spring effect on | 5.8 |
| 1 | Constant Force | FF mode 3 (only if bits 0 and 2 are 0) | 4.4 |
| 2 | Force Linear Up (Run Profile Mode) | Use the force curve, FF mode 1 (0 = FF mode 2) | 4.2 |
| 3 | One-time Turbulence | One turbulence oscillation | 5.10 |
| 4 | Constant Turbulence | Continuous turbulence | 5.10 |
| 5 | Move to positive limit | Drive to the positive limit, then shut down | 4.7 |
| 6 | Move to negative limit | Drive to the negative limit, then shut down | 4.7 |
| 7, 8 | Sync Mode | Behaviour in synchronisation (combination of both bits) | 6.3 |
| 9 | PDO Auto Init Factory | NMT operational after boot-up | 6 |
| 10 | Auto State | Enable and home automatically after power-up | 3.2 |
| 11 | Set Offset Sensor | Force sensor zero offset (at power-up if set) | 4.7 |
| 12 | Invert Sensor Factory | Force sensor value inverted | |
| 13 | Start Homing | Home when Operation Enabled | 3.2 |
| 14 | No Init | Skip homing | 3.2 |
| 15 | Invert Position Factory | Position value inverted |
4.7Additional functions
Move to a limit and shut down
Before the system is switched off, the axis can drive to a limit. The control is then parked at a defined position while the power is off. Set 0x2101.1 bit 5 (positive limit) or bit 6 (negative limit).
Force sensor offset
Sets the force sensor to zero. If bit 11 is set at power-up, the offset runs at every start. This lets the system recover by itself when the sensor has drifted out of its valid range. BRUNNER recommends leaving it on. It has no effect when the force comes from the motor current.
5Force control loop
The force control loop runs in the drive every 400 µs (2.5 kHz). It passes the measured force through a chain of stages; at the end a speed set-point goes to the velocity regulator.
Because the loop runs inside the device, an external controller such as CLS2Sim does not need a high update rate in FF modes 1 and 2. In FF mode 3 the external controller closes the loop itself, so the CAN communication must be fast and regular.
Signal names: AF = actual force, P = position, SC = scale factor, EF = elimination force, FO = force offset, F1 = set force, VF1 = virtual force, V1 – V6 = speed set-point after each stage.
Which stage works in which FF mode
| Stage | 1 Profile | 2 Friction | 3 Constant | 4 DirectX |
|---|---|---|---|---|
| Stick angle compensation | ✓ | ✓ | ✓ | ✓ |
| Trim | ✓ | ✓ | ✓ | – |
| Scale factor | ✓ | – | – | – |
| Friction eliminator | ✓ | ✓ | ✓ | ✓ |
| Wing airflow | ✓ | – | – | – |
| Spring effect | ✓ | ✓ | – | – |
| Damping | ✓ | ✓ | – | ✓ |
| Dynamic response | ✓ | – | – | – |
| Turbulence | ✓ | ✓ | ✓ | ✓ |
| Autopilot | ✓ | ✓ | ✓ | ✓ |
| Range limit | ✓ | ✓ | ✓ | ✓ |
| Synchronisation (MCC) | ✓ | ✓ | ✓ | – |
5.1Force sensor selection
Selects and configures the force sensor. Parameters marked Factory are preset and should not be changed.
| Object | Name | Description |
|---|---|---|
| 0x2107.0 | FF Torque Sensor Factory | 0 = external sensor (analogue input 0x2036) · 1 = motor current (0x6077, ‰ of rated torque) · 2 = CAN strain gauge, PDO 16 bit · 3 = CAN strain gauge, PDO 14 bit · 4 = CAN strain gauge, PDO 12 bit · 10 = I²C strain gauge |
| 0x209D.0 | Node ID Force Sensor Factory | Node-ID of the CAN strain gauge (sensor types 2 – 4) |
| 0x209E.0 | Force Sensor Ext Sync RO | Value of the second channel with dual strain gauges (types 2 – 10) |
| 0x209F.0 | Force Sensor Ext RO | Value of the strain gauge (types 2 – 10) |
| 0x20A0.0 | Turn Force Sensor Ext Factory | Swaps 0x209E and 0x209F (types 2 – 10) |
| 0x2170.0 | Current Offset | Constant current offset (type 1, motor current, only) |
| 0x211B.0 | FF Sensor Error | Maximum force value; above it a force sensor error is raised. Also limits the virtual force to 80 %. Change takes effect after a restart. |
5.2Stick angle compensation
Compensates the weight of the grip in rotating systems, where the grip's weight adds to the measured force depending on the stick angle. Active when Force Compensation Max is greater than zero.
| Object | Name | Description |
|---|---|---|
| 0x211D.7 | Force Compensation Max | Maximum compensation, internal units. 0 = off. |
| 0x211D.8 | Current Force Compensation RO | Compensation value applied now |
| 0x211D.9 | Force Compensation Gear Factor | 1 (default) = maximum compensation at maximum position < 1000: compensate positive and negative side 1001 – 1999: negative side only, factor = value − 1000 ≥ 2001: positive side only, factor = value − 2000 |
5.3Trim
The trim moves the zero point of the force curve. The curve is evaluated at x = 0x6064 + trim, so the zero point lies at 0x6064 = −trim. The trim is the trim position 0x2116 plus the offset 0x2115. To let an external controller trim smoothly without jitter, large trim changes can be ramped.
| Object | Name | Description |
|---|---|---|
| 0x2116.0 | Trim Position RW | Zero point of the force curve |
| 0x2115.0 | Trim Offset RW | Offset added to the trim position |
| 0x211C.0 | Trim Step RW | Speed at which a trim value changed from outside (0x2116) is taken over. 0 = immediately. > 0 = the internal trim moves by this value every 100 µs (10 kHz) until it reaches the new trim position. |
| 0x2100.9 | Trim Ramp RW | 1 = fastest ramp … 20 = slowest ramp. Works together with Trim Step 0x211C. |
5.4Scale factor
In aircraft with manual controls, the control forces rise with the square of the airspeed: soft near the stall, very stiff near VNE. The scale factor reproduces this by scaling all nine profile points at once, so only one value has to be sent while flying.
Examples: 100 % = curve as entered · 200 % = double force · 50 % = half force · 20 % = minimum. Above 100 % the breakout force at the centre is not raised. Details, return scale factor and one-sided scaling: 4.2.
| Object | Name | Description |
|---|---|---|
| 0x2114.0 | Scale Factor RW | 20 – 1000 %. Active in Profile Force Mode only. |
| 0x2171.0 | Reverse Scale Factor RW | Used while the stick returns to the centre, if > 19 |
| 0x211E.0 | Scale Factor Step RW | 0 = immediately. > 0 = the scale factor moves by this value every ≈ 40.8 ms. |
5.5Friction eliminator
Removes small amounts of mechanical friction and a small residual sensor offset. This helps the axis to centre accurately in Profile Force Mode.
| Object | Name | Description |
|---|---|---|
| 0x211D.1 | Enable Friction Eliminator | 1 = on |
| 0x211D.2 | Friction Value | Maximum elimination force. Too high a value is felt when moving the control. |
| 0x211D.5 | Friction Time | Time in ms until the full friction value is reached |
Finding the right friction value
- Disable the eliminator.
- Move the control in the negative direction, let go, read the force.
- Move it in the positive direction, let go, read the force.
- Use the larger absolute value as Friction Value. If the effect is noticeable, increase Friction Time or reduce the value.
5.6Low-speed fade-out (wing airflow)
Without airflow, on the ground or near the stall, the controls go slack and the elevator hangs forward. Below the scale factor 0x211F two things happen: the force above 0x6071 fades out linearly (flat at 0x6071 at a scale factor of 19, formula in 4.2), and the offset force 0x211A pulls the control. Works in Profile Force Mode only.
| Object | Name | Description |
|---|---|---|
| 0x211F.0 | Manual Offset Off Pos | Scale factor below which the curve fades out |
| 0x211A.0 | Manual Offset Force | Pulling force at the lowest scale factor (20 %), falling linearly to 0 at 0x211F |
5.7Profile calculation
Calculates the set force (F1) from the force profile, the position and the trim, and outputs it as 0x2093 Virtual Force. From the difference between measured force and set force it calculates the speed set-point V1.
5.8Spring effect (move back)
With move back on, the axis returns to the zero position by itself. The strength is set with 0x2102 P Move Back: 100 % = no effect, 500 % = strongest spring, standard 200 %. Too high a value can make the system oscillate. Not active in Constant Force Mode.
| Object | Name | Description |
|---|---|---|
| 0x2101.1 bit 0 | Move Back | 1 = on |
| 0x2102.0 | P Move Back | 100 – 500 %, default 200 % |
5.9Damping and dynamic response
When the measured force Fs exceeds the virtual force plus friction, the stick moves:
if |Fs| > |Fvirtual + friction − 0x2100.B|:
speed = (|Fs| − |Fvirtual + friction|) × 0x2100.1 / 0x2100.2
limited to min(0x607F, 0x6080), output 0x60FF
else: speed = 0
The direction comes from the sign of the measured force. With speed 0 a single axis holds its position; in master/slave synchronisation it follows the partner. The larger the fraction 0x2100.1 / 0x2100.2, the lower the damping; too little damping makes the system oscillate. 0x2100.2 can be replaced position-dependently by the damping profile: positions in 0x20A5, values in 0x20A6.
Dynamic response lets the control return to centre faster. Depending on the actual velocity, it reduces the damping denominator. Setting: 0 = off, 1 – 1000 %. Too high a value can cause oscillation.
| Object | Name | Description |
|---|---|---|
| 0x2100.1 | P Force Numerator | Damping fraction, numerator |
| 0x2100.2 | P Force Denominator | Damping fraction, denominator |
| 0x2100.B | Force Offset | Permanent force offset in force sensor units, taken into account in the comparison above |
| 0x20A5 | Damping Profile Position | Positions of the damping profile |
| 0x20A6 | Damping Profile | Damping values at the positions in 0x20A5; replace 0x2100.2 position-dependently |
| 0x607F / 0x6080 | Max profile velocity / max motor speed | Speed limit |
| 0x60FF.0 | Target Velocity RO | Resulting speed set-point |
| 0x2182.0 | Dynamic Response | 0 = off, 1 – 1000 % (FF mode 1 only) |
| 0x606C.0 | Actual Velocity RO | Input for the dynamic response |
5.10Turbulence generator
Two independent generators. Generator 1 is meant for low frequencies (turbulence), generator 2 for higher frequencies such as engine vibration. Both use the same waveform.
| Object | Name | Description |
|---|---|---|
| 0x2101.1 bit 3 | One-time Turbulence | 1 = one oscillation; its duration is the turbulence time |
| 0x2101.1 bit 4 | Constant Turbulence | 1 = continuous oscillation; its period is the turbulence time |
| 0x2108.0 | Turbulence Force, gen. 1 | Amplitude |
| 0x2109.0 | Turbulence Time, gen. 1 | Period in 1 ms |
| 0x2099.0 | Turbulence Force, gen. 2 | Amplitude |
| 0x209A.0 | Turbulence Time, gen. 2 | Period in 100 µs |
| 0x2173.0 | Waveform | 0 = square (default) · 1 = sine · 2 = triangle · 3 = sawtooth down · 4 = sawtooth up |
5.11Autopilot
Moves the axis to a target position with a limited force and a maximum speed. If the pilot pushes harder than the autopilot force, the axis gives way and returns as soon as the force falls below the limit. The autopilot does not disconnect by itself; the application (for example CLS2Sim) has to switch it off. While the autopilot runs, most other stages are inactive.
| Object | Name | Description |
|---|---|---|
| 0x2101.4 | Autopilot Mode | 0 = disabled · 1 = enabled |
| 0x2117.0 | Autopilot Position | Target position |
| 0x2118.0 | Autopilot Position Force | Maximum force |
| 0x2098.0 | Autopilot Speed | Maximum speed |
| 0x6067.0 | Position Window | The autopilot stops moving inside this window. Shared with the profile mode. |
| 0x2100.4 | Position Mode Ramp | Lower value = steeper ramp. Increase if the axis oscillates around the target. |
5.12Range limit
Keeps the axis inside the software limits and brakes it with the stop ramp. Objects and warnings: see 3.7 Position limits.
6Synchronisation (MCC)
For multi-crew cooperation (MCC) training, two axes such as captain's and first officer's aileron are coupled. The two units exchange PDOs directly; no master controller is needed. Synchronisation starts as soon as both devices have finished homing.
6.1Node-ID assignment
The node-ID is set in 0x2201. Use these IDs so that CLS2Sim and the synchronisation find the right partner.
| Axis | Unit 1 (captain) | Unit 2 (first officer) |
|---|---|---|
| Aileron | 1 | 3 |
| Elevator | 2 | 4 |
| Rudder | 5 | 6 |
| Collective | 7 | 8 |
| Brake left | 101 | 103 |
| Brake right | 102 | 104 |
| Trim elevator | 105 | 106 |
| Trim aileron | 107 | 108 |
| Trim rudder | 109 | 110 |
| Throttle 1 – 4 | 111 – 114 (shared) | |
| Speed brake | 115 (shared) | |
| Nose wheel | 116 | 117 |
| Seat shaker | 118 | 119 |
6.2Old and new synchronisation
Two methods exist. The better one for each device is configured at the factory.
Old sync (since 2010)
+ Robust against communication problems
+ Supported by all devices
− Low or flat force curves can make the axes lag each other
− Position offset between the axes possible while moving
Both units: 0x2181.1 = 0
New sync (since 2023)
+ Accurate also with low forces and flat curves — the main reason for it
− Not supported by all devices
− Must be tested on each installation
− Master and slave must be configured
Captain 0x2181.1 = 3 (master), first officer = 2 (slave)
6.3Parameters
Both units must have the same values, except the destination node-ID and, with new sync, the sync type.
| Object | Name | Description |
|---|---|---|
| 0x2101.2 | Destination Node-ID | Node-ID of the partner axis. Example: captain's aileron (node 1) → 3. Without synchronisation set it to the device's own node-ID. |
| 0x2181.1 | Sync Type | 0 = old sync · 2 = new sync, slave · 3 = new sync, master. Store and restart after changing. |
| 0x2100.3 | Velocity Factor (old sync) | Higher = slower, softer coupling. Too low causes oscillation. Keep the default. |
| 0x2181.2 | Velocity Factor (new sync) | As above, for new sync. |
| 0x2101.7 | Position Follow Off | 1 = position is not followed; trim and autopilot stay synchronised. 0 = normal. |
| 0x2101.1 bit 7, 8 | Sync Mode | Behaviour of the unit in synchronisation, see below |
| 0x2101.1 bit 9 | PDO Auto Init Factory | Switches NMT to operational after boot-up (on by default). Do not change it when a force sensor is connected over CAN. |
Sync mode: 0x2101.1 bits 7 and 8
| Bit 7 | Bit 8 | Behaviour of the unit |
|---|---|---|
| 0 | 0 | Follows the master/slave rules |
| 1 | 0 | Follows the master/slave rules |
| 0 | 1 | Follows the partner; its own force input has no effect |
| 1 | 1 | Unit blocks |
7Fast Communication Mode
For external real-time controllers that write Target Torque in Constant Force Mode. Position and force are sent on change, up to 1 kHz. This allows own profiles and effects in the controller. FF modes 1 and 2 also work, but are less practical this way.
| 0x2091.0 PDO Mapping Type | Mapping | Synchronisation |
|---|---|---|
| 0 | Standard (default, internal use) | on |
| 1 | Customer setting 1 | off |
| 2 | Customer setting 2 | off |
| 3 | Customer setting 3 | off |
Store the value and restart the device to activate the new mapping. Mapping type 0 is not documented; it can be read from the object dictionary.
7.1Receive PDOs (to the device)
| PDO | Comm. object | COB-ID | Mapping object | Content |
|---|---|---|---|---|
| RPDO1 | 0x1400 | 0x280 + destination node-ID | 0x1600 | 0x6071 Target Torque (16) · 0x2114 Scale Factor (16) · 0x2101.1 FF control word (16) · 0x2101.3 Update bit (16) |
| RPDO2 | 0x1401 | 0x380 + destination node-ID | 0x1601 | 0x2100.2 P Force Denominator (16) · 0x2116 Trim Position (32) |
| RPDO3 | 0x1402 | 0x53C (reserved) | 0x1602 | reserved |
| RPDO4 | 0x1403 | 0x400 + destination node-ID | 0x1603 | 0x2108 Turbulence Force 1 (16) · 0x2109 Turbulence Time 1, ms (16) · 0x2099 Turbulence Force 2 (16) · 0x209A Turbulence Time 2, 100 µs (16) |
7.2Transmit PDOs (from the device)
| PDO | Comm. object | COB-ID | Inhibit time standard ×100 µs | Inhibit time dual servo ×500 µs | Event timer standard | Event timer dual servo |
|---|---|---|---|---|---|---|
| TPDO1 | 0x1800 | 0x280 + node-ID | 10 (1 ms, max. 1 kHz) | 2 (1 ms, max. 1 kHz) | 100 ms | 100 ms |
| TPDO2 | 0x1801 | 0x380 + node-ID | 10 (1 ms, max. 1 kHz) | 2 (1 ms, max. 1 kHz) | 200 ms | 200 ms |
| TPDO3 | 0x1802 | 0xC0000380 (disabled) | reserved | |||
| TPDO4, type 1 | 0x1803 | 0x400 + node-ID | 0 (off) | 1000 (500 ms) | 500 ms | 1 s |
| TPDO4, type 2/3 | 0x1803 | 0x400 + node-ID | 100 (10 ms, max. 100 Hz)* | not supported | 500 ms* | not supported |
* not supported by all devices
| Mapping object | Content |
|---|---|
| 0x1A00 | 0x2105 Actual Force (16) · 0x6064 Actual Position (32) · 0x6041 Statusword (16) |
| 0x1A01 | 0x606C Actual Velocity (32) · 0x2089.1 or 0x60FD Digital Inputs (32) |
| 0x1A02 | reserved |
| 0x1A03 type 1 | 0x2031.1 Drive Temperature (16) · 0x603F Error Code (16) · 0x6079 DC link circuit voltage (32) |
| 0x1A03 type 2 | 0x2031.1 Drive Temperature (16) · 0x603F Error Code (16) · 0x2036 Analogue Input 1 (32) |
| 0x1A03 type 3 | 0x2038 Analogue Input 2 (32) · 0x2036 Analogue Input 1 (32) |
8CANopen and object dictionary
CANopen is a higher-layer protocol and device profile family on top of CAN. The CAN bus carries the CANopen messages. BRUNNER drives implement CiA 301 (communication profile) and CiA 402 (drives and motion control). Background: CiA CAN knowledge.
The object dictionary of each CLS device is shown in the CANopen Commander under CAN Device Profile. The device description files (XDD) for integration into other tools are in the Commander installation folder, subfolder CANDeviceProfiles.
A complete list of all objects mentioned in this guide is in section 11.
9Software and tools
Download all tools from the BRUNNER download area. The software runs on Windows 11, 10, 8.1 and 7.
9.1CANopen Commander
Setup and service tool for CANopen devices. It monitors CAN traffic, supports Layer Setting Services (LSS) and sends NMT, SDO and raw CAN messages. Device plugins add functions such as storing and restoring parameters, firmware updates and CiA 402 drive diagnostics. Device profiles can be saved and loaded to set up networks faster.
It connects to the BRUNNER E2CAN Gateway (Ethernet or driverless USB-HID) or directly to BRUNNER devices with a USB-HID interface. Quick start manual: CANopenCommander_QuickStartManual.pdf in the installation folder.
9.2CLS2Sim
Connects BRUNNER CLS devices to flight simulation software. Force by deflection, force increase with speed, trim (with or without BRUNNER electric trim wheels), engine vibration, turbulence, runway effects and stick shaker can be configured for up to 20 axes on the CAN bus. The simulator's autopilot can drive the controls.
Direct support for Prepar3D, FSX, X-Plane and Microsoft Flight Simulator 2020/2024. Other simulators connect through a TCP/IP or UDP remote interface to read positions, buttons, forces and status, and to set trim, autopilot or force profiles. CLS2Sim online help
9.3Simux
Simux connects your simulator with your controllers, bringing input bindings and configurable force effects into one application. Build a common setup, tailor it to individual aircraft, and use aircraft or category assignments to switch profiles automatically.
Supports Microsoft Flight Simulator 2020 and 2024, X-Plane 11 and 12, and DCS World. Download, quick start and documentation: simux.brunner-innovation.swiss
9.4USB Config Tool
Calibrates the axes of USB game controllers and shows buttons, hat switches and axes, similar to the Windows game controller settings. It also switches CLS devices with USB-HID between CLS2Sim and DirectX mode, and selects the grip type of CLS-E and CLS-P joysticks.
9.5CANopen Tunnel
Connects CLS devices over Ethernet instead of a continuous CAN cable, so devices can be in different rooms or at different sites. Node-IDs do not have to be coordinated across sites. Error handling copes with higher network delays on long connections. Documentation: CANopenTunnel_UserGuide.pdf in the Doc folder of the download.
9.6E2CAN IP Config Tool
Sets the IP address of E2CAN gateways and SMART I/O devices.
10CAN bus wiring
CAN is robust against noise, reliable and simple to wire. Its limits are small data packets, moderate data rates and cycle times that can vary. Real installations lose signal margin through cables, connectors, stubs and ground potential differences, so the achievable number of nodes and cable lengths are lower than the theoretical values.
10.1RJ45 pin assignment
All BRUNNER CLS devices use RJ45 connectors for CAN. Most devices have two connectors for daisy-chaining.
| Pin | Signal | Description |
|---|---|---|
| 1 | CAN_H | CAN high |
| 2 | CAN_L | CAN low |
| 3, 7 | CAN_GND | Ground |
| 4, 5, 6, 8 | — | Not connected |
10.2Cable and baud rate
Standard Ethernet cable, category 5 or better. Keep each cable between two devices at 3 m or less, and as short as possible. The CAN baud rate of all BRUNNER CLS devices is fixed at 1 Mbit/s.
10.3Termination
A CAN bus needs a 120 Ω resistor between CAN_H and CAN_L at both physical ends of the bus. Without them, signals are reflected at the cable ends and communication errors follow. The ends are the two devices farthest apart along the cable, not in the room.
Most installations work with the two standard terminators. Larger systems with more than four devices, such as the MCC installation with gateway in 10.5, need a third terminator; without it the communication does not work reliably. Check the bus with the quality test (10.6) after every change. Contact BRUNNER before fitting a fourth terminator.
10.4Termination per device
| Article | Device | Termination |
|---|---|---|
| GER.1030 | CLS-P Yoke | none, needs external terminator |
| GER.1031 | CLS-P Rudder | none, needs external terminator |
| GER.1032 | CLS-P Cyclic | none, needs external terminator |
| GER.1079 | CLS-B Yoke | fixed 120 Ω |
| GER.1081 | CLS-P Collective | 120 Ω, internal switch |
| GER.1088 | E2CAN Gateway | none, needs external terminator |
| GER.1088 | E2CAN MKII Gateway | 120 Ω, internal switch |
| GER.1089 | L-Motion 2000 N | 120 Ω, internal switch |
| GER.1097 | CLS-P Rudder | 120 Ω, internal switch |
| GER.1104 | CLS-E Yoke | fixed 120 Ω |
| GER.1104 | CLS-E MKII Yoke | 120 Ω, object 0x2200 |
| GER.1130 | ULC Drive, up to Rev E | none, needs external terminator |
| GER.1130 | ULC Drive, from Rev F | 120 Ω, object 0x2200 |
| GER.1137 | CLS-H Yoke | fixed 120 Ω |
| GER.1141 | CLS-P Joystick | 120 Ω, object 0x2200 |
| GER.1146 | CLS-P Yoke | 120 Ω, internal switch |
| GER.1147 | BLDC Drive | 120 Ω, object 0x2200 |
| GER.1158 | CLS-E Rudder | 120 Ω, object 0x2200 |
| GER.1160 | CLS-E Joystick | 120 Ω, object 0x2200 |
| GER.1164 | CLS-B Yoke | 120 Ω, internal switch |
| GER.1168 | Direct Drive | 120 Ω, internal switch |
| GER.1170 | CLS-B Rudder | 120 Ω, internal switch |
| GER.1179 | CLS-E NG Yoke | fixed 120 Ω |
| GER.1219 | CLS-B Collective | 120 Ω, internal switch |
| GER.1224 | CLS-P MK2 Cyclic | 120 Ω, internal switch |
| GER.1245 | L-Motion 200 mm | 120 Ω, internal switch |
| GER.1247 | CLS-E MK2 Joystick | 120 Ω, internal switch |
| PRT.5245 | SMART I/O | 120 Ω, internal switch |
Where a device is listed twice, the higher article number is the newer version. On devices with object 0x2200, the internal terminator is switched on with 1 and off with 0.
10.5Example installation
In this example the E2CAN gateway also needs its termination switched on.
The two CAN connectors of the E2CAN gateway are looped through (daisy chain); the gateway does not split the bus into two segments. This installation therefore needs three terminators.
10.6CAN bus quality test
- CLS2Sim communication statistics. Connect with CLS2Sim and open the communication statistics with the Details button. Timeouts/s and Timeouts tot should stay at 0. A few timeouts per hour are acceptable. If a value keeps rising, check termination and cable lengths. The bus load should be below 50 %, and no CAN bus errors should be active.
- Reset the gateway statistics. Click the IP address in CLS2Sim, or enter it in a browser, to open the web page of the E2CAN Gateway MK2 or SMART I/O. Under Commands, apply Reset Stats.
- Check the CAN interface counters. Open CAN Interface. All counters should stay at zero, except Tx FIFO Level Max and Rx FIFO Level Max. If a counter rises, check termination and cable lengths.
11Object index
All objects in this guide, sorted by index. Use the filter or the search at the left.
| Object | Name | Section |
|---|---|---|
| 0x1400 – 0x1403 | RPDO communication parameters | 7.1 |
| 0x1600 – 0x1603 | RPDO mapping | 7.1 |
| 0x1800 – 0x1803 | TPDO communication parameters | 7.2 |
| 0x1A00 | 0x2105 Actual Force (16) · 0x6064 Actual Position (32) · 0x6041 Statusword (16) | 7.2 |
| 0x1A00 – 0x1A03 | TPDO mapping | 7.2 |
| 0x1A01 | 0x606C Actual Velocity (32) · 0x2089.1 or 0x60FD Digital Inputs (32) | 7.2 |
| 0x1A02 | reserved | 7.2 |
| 0x1A03 type 1 | 0x2031.1 Drive Temperature (16) · 0x603F Error Code (16) · 0x6079 DC link circuit voltage (32) | 7.2 |
| 0x1A03 type 2 | 0x2031.1 Drive Temperature (16) · 0x603F Error Code (16) · 0x2036 Analogue Input 1 (32) | 7.2 |
| 0x1A03 type 3 | 0x2038 Analogue Input 2 (32) · 0x2036 Analogue Input 1 (32) | 7.2 |
| 0x2031.1 | Drive Temperature | 7.2 |
| 0x2036.0 | Analogue Input 1 | 7.2 |
| 0x2038.0 | Analogue Input 2 | 7.2 |
| 0x2057.0 | Homing Delay | 3.5 |
| 0x2058.0 | Homing Current Limit | 3.5 |
| 0x2059.0 | Last Homing Error | 3.6 |
| 0x205A.1 | Homing Option | 3.5 |
| 0x205A.2 | Homing Option KP | 3.5 |
| 0x2089.1 | Digital Inputs | 7.2 |
| 0x2091.0 | PDO Mapping Type | 7 |
| 0x2093.0 | Virtual Force | 4.2, 5.7 |
| 0x2098.0 | Autopilot Speed | 5.11 |
| 0x2099.0 | Turbulence Force, gen. 2 | 5.10 |
| 0x209A.0 | Turbulence Time, gen. 2 | 5.10 |
| 0x209C.0 | Software negative limit | 3.7 |
| 0x209C.0 | Neg Limit | 4.2 |
| 0x209D.0 | Node ID Force Sensor | 5.1 |
| 0x209E.0 | Force Sensor Ext Sync | 5.1 |
| 0x209F.0 | Force Sensor Ext | 5.1 |
| 0x20A0.0 | Turn Force Sensor Ext | 5.1 |
| 0x20A1.1 – .12 | Force Profile Position | 4.2 |
| 0x20A2.1 – .12 | Friction Profile Position | 4.2 |
| 0x20A3.1 – .12 | Friction Profile | 4.2 |
| 0x20A5 | Damping Profile Position | 5.9 |
| 0x20A6 | Damping Profile | 5.9 |
| 0x2100.1 | P Force Numerator | 5.9 |
| 0x2100.2 | P Force Denominator | 5.9 |
| 0x2100.3 | Velocity Factor (old sync) | 6.3 |
| 0x2100.4 | Position Mode Ramp | 5.11 |
| 0x2100.8 | Soft Limit Stop Ramp | 3.7 |
| 0x2100.9 | Trim Ramp | 5.3 |
| 0x2100.B | Force Offset | 5.9 |
| 0x2100.C | Select Profile Mode | 3.7 |
| 0x2100.C | Profile Mode | 4.2 |
| 0x2100.E | Subindex in hexadecimal: E = 14, 10 = 16 | 1 |
| 0x2100.E bit 1 | Init Always | 3.2 |
| 0x2100.E bit 2 | Disable Limits | 3.7 |
| 0x2100.F | One-sided scaling | 4.2 |
| 0x2100.F | One-sided Scaling | 4.2 |
| 0x2100.10 | Enable Detent Move Back | 4.2 |
| 0x2101.1 bit 0 | Move Back | 4.2, 4.3, 5.8 |
| 0x2101.1 bit 1 | Constant Force | 4.4 |
| 0x2101.1 bit 2 | Force Linear Up (Run Profile Mode) | 4.2 |
| 0x2101.1 bit 2 | Run Profile Mode | 4.3 |
| 0x2101.1 bit 3 | One-time Turbulence | 5.10 |
| 0x2101.1 bit 4 | Constant Turbulence | 5.10 |
| 0x2101.1 bit 7, 8 | Sync Mode | 6.3 |
| 0x2101.1 bit 9 | PDO Auto Init | 6.3 |
| 0x2101.1 bit 10 | Auto State | 3.2 |
| 0x2101.1 bit 13 | Single bit in a bit-field object, counted from bit 0 (least significant) | 1 |
| 0x2101.1 bit 13 | Start Homing | 3.2 |
| 0x2101.1 bit 14 | No Init | 3.2 |
| 0x2101.1 bit 15 | Invert Position | 4.2 |
| 0x2101.2 | Destination Node-ID | 6.3 |
| 0x2101.4 | Autopilot Mode | 5.11 |
| 0x2101.7 | Position Follow Off | 6.3 |
| 0x2102.0 | P Move Back | 5.8 |
| 0x2107.0 | FF Torque Sensor | 5.1 |
| 0x2108.0 | Turbulence Force, gen. 1 | 5.10 |
| 0x2109.0 | Turbulence Time, gen. 1 | 5.10 |
| 0x2113.1 – .12 | Force Profile | 4.2 |
| 0x2114.0 | Object index 0x2114, subindex 0 | 1 |
| 0x2114.0 | Scale Factor | 4.2, 4.2, 5.4 |
| 0x2115.0 | Trim Offset | 5.3 |
| 0x2116.0 | Trim Position | 5.3 |
| 0x2117.0 | Autopilot Position | 5.11 |
| 0x2118.0 | Autopilot Position Force | 5.11 |
| 0x2119.0 | Software positive limit | 3.7 |
| 0x2119.0 | Pos Limit | 4.2 |
| 0x211A.0 | Manual Offset Force | 5.6 |
| 0x211B.0 | Sensor Error | 4.2 |
| 0x211B.0 | FF Sensor Error | 5.1 |
| 0x211C.0 | Trim Step | 5.3 |
| 0x211D.1 | Enable Friction Eliminator | 5.5 |
| 0x211D.2 | Friction Value | 5.5 |
| 0x211D.5 | Friction Time | 5.5 |
| 0x211D.7 | Force Compensation Max | 5.2 |
| 0x211D.8 | Current Force Compensation | 5.2 |
| 0x211D.9 | Force Compensation Gear Factor | 5.2 |
| 0x211D.B | Constant Friction Value | 4.2 |
| 0x211E.0 | Scale Factor Step | 4.2, 4.2, 5.4 |
| 0x211F.0 | Manual Offset Off Pos | 4.2, 5.6 |
| 0x2170.0 | Current Offset | 5.1 |
| 0x2171.0 | Reverse Scale Factor | 4.2, 4.2, 5.4 |
| 0x2173.0 | Waveform | 5.10 |
| 0x2180.1 | Enable | 4.5 |
| 0x2180.10 | Global Force Scale | 4.5 |
| 0x2180.12 | Spring Effect Gain | 4.5 |
| 0x2180.13 | Global Device Damping | 4.5 |
| 0x2180.14 | Periodic Effect Gain | 4.5 |
| 0x2180.15 | Constant Force Effect Gain | 4.5 |
| 0x2180.16 | Damper Effect Gain | 4.5 |
| 0x2181.1 | Sync Type | 6.3 |
| 0x2181.2 | Velocity Factor (new sync) | 6.3 |
| 0x2182.0 | Dynamic Response | 5.9 |
| 0x2200.0 | CAN termination on/off | 10.4 |
| 0x2201.0 | Node-ID | 6.1 |
| 0x603F.0 | Error Code | 7.2 |
| 0x6041 bit 12 | Homing attained | 3.6 |
| 0x6041 bit 13 | Homing error | 3.6 |
| 0x6060.0 | Modes of Operation | 2 |
| 0x6067.0 | Position Window | 4.2, 5.11 |
| 0x606C.0 | Actual Velocity | 5.9 |
| 0x6071.0 | Target Torque | 4.2, 4.3, 4.4 |
| 0x6079.0 | DC link circuit voltage | 7.2 |
| 0x607C.0 | Home Offset | 3.5 |
| 0x607D.1 / .2 | Min / Max Position Limit | 3.5 |
| 0x607F / 0x6080 | Max profile velocity / max motor speed | 5.9 |
| 0x6098.0 | Homing Method | 3.5 |
| 0x6099.1 | Homing Speed | 3.5 |
| 0x60FD.0 | Digital Inputs | 7.2 |
| 0x60FF.0 | Target Velocity | 5.9 |
12Glossary and revisions
| Term | Meaning |
|---|---|
| CLS | Control loading system: a control (stick, yoke, rudder…) with active force feedback |
| Homing | Referencing the position after power-up (also called initialisation) |
| FF mode | One of the four force feedback modes inside CiA 402 mode −1 |
| Trim point | Zero position of the force profile |
| MCC | Multi-crew cooperation: two synchronised sets of controls |
| PDO / SDO | Process data object (fast, cyclic) / service data object (parameter access) |
| NMT | Network management: pre-operational, operational, stopped |
| Strain gauge (DMS) | Force sensor based on a Dehnungsmessstreifen |
| PMSM | Permanent magnet synchronous motor |
| Version | Date | Changes |
|---|---|---|
| 1.2 | 27.12.2024 | Last draw.io version |
| 2.0 | 05.10.2026 | New HTML edition: searchable, responsive, print-ready. Homing rewritten with all methods and interactive demonstration. Consolidated bit map of 0x2101.1, object index, corrected cross-references and PDO tables, device list sorted, termination check added. |