Out of the boxEvery CLS device works with its factory settings. Use this guide only when you need to adjust ranges, forces or damping.
CANopen CiA 301 / 402All objects are shown as index.subindex in hexadecimal.
Supportsupport@brunner-innovation.swiss or a ticket in the BRUNNER Helpdesk

BRUNNER Elektronik AG

As a modern, family-owned technology company we are a trusted and reliable partner to numerous companies across various industries and markets since 1968.

Our ability to handle all corporate core processes, from development to production and customer support, fully in-house creates sustainable advantages for our customers and partners: short response times, high flexibility and an integral understanding of quality. Our engaged and highly qualified employees share our enthusiasm for working for our customers, take over responsibility and live the values of team spirit and fairness.

With convincing solutions in the field of electronics, intelligent drives and innovative simulation products and components we address customers in markets like mechanical engineering, packaging industry, process engineering, medical technology, robotics and simulation-based training.

Control Loading Systems since 2009

We developed a portfolio of leading Control Loading Systems in close cooperation with experienced pilots and experts from the flight training industry. Our extensive experience with modern Drive and Control technologies and our passion for aviation has been the foundation and driving force behind our product development initiative.

All our CLS devices provide realistic force feedback using advanced control technology, feature adjustable positions and angles, and are compatible with a wide range of simulation software and platforms. They offer a highly realistic and immersive training experience, making them an excellent choice for professional pilots, flight simulator enthusiasts, and other industries that require realistic control feedback.

1About this guide

Control loading systems are complex devices. They work out of the box, but professional and certified simulators often need adjustments: a reduced range of motion, different forces, more or less damping, or two synchronised seats. This guide explains the functions behind those settings and the CANopen objects that control them.

The main subject is the Force Feedback Mode (0x6060 = −1), in which all BRUNNER CLS devices run. Settings are usually made with Simux, CLS2Sim or the CANopen Commander.

How to read object references

NotationMeaning
0x2114.0Object index 0x2114, subindex 0
0x2101.1 bit 13Single bit in a bit-field object, counted from bit 0 (least significant)
0x2100.ESubindex in hexadecimal: E = 14, 10 = 16
RW RORead/write or read-only
FactoryPreset at the factory. Changing it needs factory access; contact BRUNNER.
SafetyA CLS device can move on its own and apply high forces. Keep hands and objects away from the controls during homing, sensor offset and autopilot movements. Never disable software limits on a device that is installed in a cockpit.

Support, training and contact

Technical support

E-mail support@brunner-innovation.swiss or open a ticket in the Helpdesk. Remote support by TeamViewer is available on an hourly basis and recommended for complex systems and first installations.

Sales, training, support hours

sales@brunner-innovation.swiss
Training at your site or at BRUNNER in Hittnau.

BRUNNER Elektronik AG

Industriestrasse 27
8335 Hittnau, Switzerland
+41 44 953 10 10
info@brunner-innovation.swiss
www.brunner-innovation.swiss

2Operating modes

BRUNNER CLS devices communicate over CANopen. The stack follows CiA 301 (communication profile) and CiA 402 (drives and motion control). BRUNNER is a member of CAN in Automation.

The operating mode is selected with 0x6060 Modes of Operation. The device selects the Force Feedback Mode automatically at start-up.

0x6060ModeStatus on CLS devices
−1Force Feedback Mode (BRUNNER specific)Active, selected automatically
1Profile Position ModeDisabled
3Profile Velocity ModeDisabled
4Profile Torque ModeDisabled
6Homing ModeNot used directly — homing runs inside the Force Feedback Mode, see 3
7Interpolated Position ModeDisabled
8 – 10Cyclic Synchronous Position / Velocity / Torque ModeDisabled
Why the other modes are disabledThe standard CiA 402 modes are implemented, but in those modes the software limits and the other protection functions of the Force Feedback Mode are not active. Wrong parameters could damage the hardware or injure the pilot.

3Homing and limits

A CLS axis with an incremental position sensor does not know where it is when it is switched on. Homing finds a known reference, sets the position counter and then hands over to force feedback. Until homing is finished, no force feedback mode is active.

Homing ends as soon as the reference is set. The axis does not drive to the centre as part of homing: once force feedback is active, the spring effect (Move Back) returns it to zero.

Factory settingsHoming method, speed and current limit are set at the factory for each device. Most of these parameters can only be changed in factory mode. Contact BRUNNER before changing them.

3.1Ranges and reference points

Three ranges are nested inside each other. The software limits are normally set to the hardware limits and are reduced only when the simulator needs a smaller range of motion.

Mechanical stop Mechanical stop Centre / zero 0x607C Home Offset HW negative limit 0x607D.1 Min Position Limit HW positive limit 0x607D.2 Max Position Limit SW negative limit 0x209C SW positive limit 0x2119 Moving range (software) Hardware range
The mechanical stops are the physical end of travel. The hardware limits lie just inside them and are calculated during homing; the distance is not fixed and differs from unit to unit. Software limits restrict the moving range in force feedback operation.

Devices with limit switches or an absolute position sensor (for example the Direct Drive solution) do not have to travel to a mechanical stop to reference themselves.

3.2When homing runs

By default a device homes once after power-up. Four settings decide when that happens:

ObjectNameEffect
0x2101.1 bit 10Auto State1 = after power-up the axis enables itself and homes once, without a command from the controller.
0x2101.1 bit 13Start Homing1 = homing starts as soon as the drive is in Operation Enabled.
0x2101.1 bit 14No Init1 = homing is skipped; the axis reports "initialised" after Operation Enabled. Position is not referenced.
0x2100.E bit 1Init Always1 = homing runs again on every 0 → 1 change of Start Homing. With 0 the device homes only once per power cycle.
Power upSensor offset if bit 11 Operation Enabledby Auto State or controller Homingmethod 0x6098 Homing attained0x6041 bit 12 = 1 Homing errorbit 13 = 1, read 0x2059 Force feedbackFF mode 1 – 4 active

3.3Homing methods: interactive demonstration

The homing method is set in 0x6098 Homing Method. Choose a method to watch the movement. You can also inject a fault to see how the device reacts and which error code it reports in 0x2059.

Homing simulator

Schematic axis. Positions and times are illustrative, not device values.

0x6064 Actual position?
Motor current / 0x20580 %
0x6041.12 Homing attained0
0x6041.13 Homing error0
0x2059 Last homing error0

    3.4The methods in detail

    Methods −1 to −4 are BRUNNER specific and reference on a mechanical stop by detecting the rise in motor current. Methods 17, 18 and 35 follow CiA 402. Method 0 does not move.

    3.5Homing parameters

    ObjectNameUnitDescriptionUsed by
    0x6098.0Homing Method—−4 … −1, 0, 17, 18, 35. See 3.4. Factoryall
    0x6099.1Homing Speedrpm (motor)Motor speed while searching the stop or switch.−4 … −1, 17, 18
    0x2058.0Homing Current LimitmACurrent at which a mechanical obstacle is detected. For −4 … −1 this is the stop detection; for 17/18 exceeding it is an error.−4 … −1, 17, 18
    0x2057.0Homing DelaymsTime the current must stay above the limit before the stop is accepted as reference.−4 … −1
    0x205A.1Homing Option—0 = standard homing; 1 = new homing, the real (measured) position is used for the calculation.−4 … −1
    0x205A.2Homing Option KP—Separate proportional gain of the regulator during homing.moving methods
    0x607C.0Home OffsetincrementsOffset of the centre position. For −4 … −1 the centre is calculated from the hardware limit; for 0 and 35 it is added to the current position.all
    0x607D.1 / .2Min / Max Position LimitincrementsHardware limits, just inside the mechanical stops (distance differs per unit). Methods −3/−4 drive to the opposite limit to check the range.−4 … −1

    3.6Status and error codes

    ObjectNameDescription
    0x6041 bit 12Homing attained RO1 = homing completed successfully.
    0x6041 bit 13Homing error RO1 = homing failed. Read 0x2059 for the reason.
    0x2059.0Last Homing Error ROError code of the last failed homing, see table below.
    0x2059ErrorMethodsTypical cause and remedy
    1Current too high17, 18The axis hit an obstacle before reaching the limit switch. Remove the obstacle, check the linkage for binding.
    2Positive limit switch active17, 18The positive limit switch is active when it should not be, e.g. already at start. Check switch and wiring. Does not occur with the stop methods −1 … −4.
    3Negative limit switch active17, 18As error 2 for the negative limit switch.
    4Position check failed−3, −4The axis met resistance before reaching the opposite hardware limit. Usually an obstacle was taken for the stop during the first search, or the mechanics changed. Check for obstacles and loose parts.
    5Force sensor out of rangeallForce sensor value invalid during initialisation. Do not touch the control during start-up. Run a sensor offset (0x2101.1 bit 11).
    10Homing timeoutall movingReference not found in time. Check homing speed, mechanics and limit switch wiring.

    3.7Position limits

    ObjectNameDescription
    0x209C.0Software negative limit RWLower end of the moving range.
    0x2119.0Software positive limit RWUpper end of the moving range. Software limits cannot exceed the hardware limits.
    0x2100.8Soft Limit Stop Ramp RWStiffness beyond a software limit: the drive adds a force that grows with the distance beyond the limit (limited to 0x7FFF and 0x6072). Lower value = harder stop, 1 = hardest stop.
    0x2100.CSelect Profile Mode RW0 = symmetric: negative limit = −0x2119
    1 = asymmetric, same slope: negative limit 0x209C
    2 = asymmetric, curve scaled to each limit: negative limit 0x209C
    In modes 1/2 the negative limit is at most −300. Effect on the force curve: 4.2.
    0x2100.E bit 2Disable Limits RW1 = software limits off. Dangerous, see warning.

    Outside a software limit the force curve is evaluated with scale factor 100 % and the stiffening force from 0x2100.8 is added, so the stop feels like a hard spring rather than a wall.

    Disable LimitsWithout software limits the axis can drive into the mechanical stops at full speed. This can damage the gearbox, the linkage or the cockpit. Use only on a test bench and never with a pilot at the controls.

    3.8Troubleshooting homing

    SymptomCheck
    Axis does not move after power-upAuto State (0x2101.1 bit 10) off and no Start Homing from the controller; or No Init (bit 14) set; or the device already homed and Init Always is 0.
    Centre is offset after every startSomething limits the travel before the real stop (cable, cockpit panel). Methods −1/−2 accept any obstacle as the stop; −3/−4 detect it with error 4.
    Homing error 5 at start-upHands on the control during start-up, or sensor drift. Enable the sensor offset at power-up (bit 11).
    Homing error 10Speed too low, heavy friction, or the limit switch never triggers (wiring).

    4Force feedback modes

    Inside the Force Feedback Mode the device runs one of four FF modes. All of them need a completed homing. By default FF mode 1 or 2 is active with a force profile that suits the device.

    4.1Overview and selection

    FF modeUseForce comes fromSelected by
    1 Profile ForceStick, yoke, rudder: force rises with deflectionForce curve: 9 points 0x2113 (18 in the extended layout), scaled by 0x21140x2101.1 bit 2 = 1
    2 Friction ForceCollective, throttle: constant friction over the full range0x6071 Target Torquebit 2 = 0 and not FF mode 3
    3 Constant ForceOwn force models in an external real-time controller0x6071 Target Torque, signedbit 1 = 1, bit 0 = 0, bit 2 = 0
    4 DirectXGames with DirectInput force feedback over USBThe game, through Windows0x2180.1 = 1

    Bits of 0x2101.1. Profile Force has priority: Constant Force only becomes active when Move Back (bit 0) and Run Profile Mode (bit 2) are both off.

    Bit 2 Run ProfileBit 1 Constant ForceBit 0 Move BackActive FF mode
    1anyany1 Profile Force
    0103 Constant Force
    00any2 Friction Force
    0112 Friction Force with move back

    4.2Profile Force Mode (FF mode 1): the force curve

    In this mode the drive behaves like a spring with a programmable characteristic. The force curve gives, for every stick position, the force the pilot has to apply before the stick moves. This force is the virtual force 0x2093. The curve is used when 0x2101.1 bit 2 = 1; with bit 2 = 0 the virtual force is the constant 0x6071 over the whole range (Friction Force Mode).

    How the control loop uses the curve

    Every 400 µs (2.5 kHz) the drive:

    1. reads the position: 0x6064 + trim position (with the autopilot active: 0x6064 only);
    2. looks up the virtual force on the force curve;
    3. adds the friction (friction profile 0x20A2/0x20A3 or constant friction 0x211D.B) and, outside the software limits, the soft-limit force;
    4. compares the result with the measured force;
    5. if the pilot pushes harder than that, moves with a speed proportional to the excess force (see 5.9).

    Forces are in the units of the force sensor selected by 0x2107, positions in increments of 0x6064. The sign of the position (after trim) decides which side of the curve is used. With trim the zero point of the curve moves to −trim.

    Scroll to zoom, drag the background to pan, double-click to reset

    Calculated with the firmware formula (integer arithmetic). Positive limit 0x2119 = 5700, 0x211B = 30000. Drag a point to change it, or type values below. In the extended layout points also move sideways; while you drag, the position is shown under the axis. Outside the software limits the soft-limit force is added on top (not shown, not part of 0x2093).

    Standard layout (symmetric, equidistant)

    Used when 0x20A1.1 and 0x20A1.2 are both 0. Only the nine points 0x2113.1 – .9 count. Point n lies at (n − 1) × step: point 1 is the centre, point 9 is at 8 × step. Both sides use the same force values; only the step width can differ.

    0x2100.C profile modeStep for x ≥ 0Step for x < 0
    0 symmetric0x2119 / 80x2119 / 8
    1 asymmetric, same slopemax(0x2119, |0x209C|) / 8same as x ≥ 0
    2 asymmetric, scaled0x2119 / 8|0x209C| / 8

    Integer division; a step of 0 is replaced by 1. Between two points the force is interpolated linearly. Beyond point 9 the slope of the last segment (8 → 9) continues; the curve does not stay flat.

    Extended layout (asymmetric, free positions)

    Active as soon as 0x20A1.1 or 0x20A1.2 is greater than 0. Then all 18 points count:

    SidePointsPositionsForces
    negative (x ≤ 0)1 – 90x20A1.1 – .90x2113.1 – .9
    positive (x > 0)10 – 180x20A1.A – .120x2113.A – .12

    Positions are entered as positive, increasing distances from the centre. From the centre to the first point the force rises linearly from 0 to the first force; after the last point it stays constant. The profile mode does not change the curve in this layout, but it still sets the negative software limit.

    Scale factor

    Both end values of a segment are multiplied by the active scale factor S / 100 before interpolating. Exception in the standard layout: the centre value 0x2113.1 is scaled only when S < 100 %. A scale factor above 100 % does not raise the breakout force, only the rest of the curve.

    The active scale factor is 0x2114. While the stick returns towards the centre it is 0x2171 Reverse Scale Factor, if that is above 19. It is 100 % while the drive is not in the FF run state and outside the software limits.

    ObjectNameDescription
    0x2114.0Scale Factor RW20 – 1000 %, 100 = values as entered
    0x2171.0Reverse Scale Factor RWScale factor for the return movement, 0 – 1000 %; used only if > 19
    0x211E.0Scale Factor Step RW0 = new value at once. > 0 = S moves by this value every 102 cycles (≈ 40.8 ms). Example: 5 takes 100 → 200 % in 20 steps ≈ 0.8 s.
    0x2100.FOne-sided scaling RW−5 … 5, only if 0x211E = 0. p > 0: S × p / 100 on the positive side; p < 0: S × |p| / 100 on the negative side.

    Centre force and centre zone

    0x6071 Target Torque (if ≥ 0) is the force at the centre and the minimum force of the whole curve: both segment end values are raised to at least 0x6071, and so is the result. It is not multiplied by the scale factor.

    The width of the centre zone is W = 0x6067. The drive limits W to 0x2119 / 20 (at least 10), on yoke devices to at least 100, and writes the limited value back to 0x6067.

    |x|Force
    0 … ¾ W0x6071, flat
    ¾ W … Wlinear from 0x6071 to the first curve value
    W … 2 Wcatch-up zone: the curve runs twice as fast and meets the normal curve at 2 W
    > 2 Wnormal curve

    With Move Back (0x2101.1 bit 0) active, the return force inside ±½ W falls linearly from 0x6071 to 0 at the centre, so the stick settles exactly on zero. The chart below shows all zones: use Centre zone to zoom in.

    If 0x6071 < 0, the centre zone and the catch-up zone are off.

    Fade-out at low scale factors

    Below the scale factor 0x211F the force above 0x6071 is reduced linearly: F = (F − 0x6071) × (S − 19) / (0x211F − 19), then raised to at least 0x6071 again. At S = 19 the curve is flat at 0x6071. This simulates the slack controls at very low airspeed.

    Limits

    • The virtual force is limited to 80 % of 0x211B Sensor Error. This limit is read once after power-up: a change of 0x211B takes effect only after a restart.
    • The result is stored in 0x2093 Virtual Force.
    • Outside the software limits a stiffening force is added (not part of 0x2093) and the scale factor is 100 %. See 3.7.

    Worked examples

    Standard layout: 0x2100.C = 0, 0x2119 = 5700 (step 712), 0x2113.1 – .9 = 50, 60, 100, 120, 140, 160, 180, 220, 260, S = 100 %, 0x6071 = 20, 0x6067 = 30, 0x211F = 40.

    x02025306010071210001424500056967000−712−3000
    F202028505051607610022026033360144

    Up to 23 (¾ W) the force is 20. It reaches point 1 (50) at W = 30 and point 9 (260) at 8 steps = 5696. Beyond, the last slope continues (7000 → 333).

    Extended layout: points 1 – 9 at 300, 800, 1500, 2200, 3000, 3800, 4500, 5100, 5700 with 40, 80, 150, 220, 300, 380, 450, 520, 600; points 10 – 18 at 400, 1000, 1800, 2600, 3400, 4200, 4800, 5300, 5700 with 60, 120, 200, 300, 400, 500, 600, 700, 800; S = 100 %, 0x6071 = 20, 0x6067 = 30.

    x−6500−5700−3000−300−15001504007001000300057006500
    F600600300403020356090120350800800

    Beyond the last point the force stays constant (600 / 800).

    Objects

    ObjectNameDescription
    0x2101.1 bit 2Force Linear Up (Run Profile Mode) RW1 = use the force curve; 0 = constant 0x6071
    0x2101.1 bit 0Move Back RW1 = spring effect returns the axis to zero, see 5.8
    0x2113.1 – .12Force Profile RWU16, force values of the points (sensor units). Standard: .1 – .9; extended: .1 – .12 (18 points)
    0x20A1.1 – .12Force Profile Position RWS32, positions of the points (increments), extended layout only. .1 or .2 > 0 switches to the extended layout.
    0x2100.CProfile Mode RW0 symmetric, 1 asymmetric same slope, 2 asymmetric scaled. Also sets the negative software limit.
    0x2119.0Pos Limit RWS32 ≥ 0, positive software limit; step width of the standard layout
    0x209C.0Neg Limit RWS32 ≤ 0, negative software limit (profile mode 1/2)
    0x2114.0Scale Factor RW20 – 1000 %
    0x2171.0Reverse Scale Factor RW0 – 1000 %, during the return movement if > 19
    0x211E.0Scale Factor Step RWRamp, see above
    0x2100.FOne-sided Scaling RW−5 … 5
    0x6071.0Target Torque RWS16, centre force and minimum force
    0x6067.0Position Window RWU32, width of the centre zone (limited by the drive). Also used by the autopilot.
    0x211F.0Manual Offset Off Pos RWScale factor below which the curve fades out
    0x211B.0Sensor Error RWVirtual force limited to 80 % of it; restart after change
    0x2101.1 bit 15Invert Position FactoryInverts the position direction
    0x2093.0Virtual Force ROS32, result of the curve (without soft-limit force)
    0x20A2.1 – .12Friction Profile Position RWPositions for the friction profile 0x20A3
    0x20A3.1 – .12Friction Profile RWFriction values at the positions in 0x20A2
    0x211D.BConstant Friction Value RWFriction over the whole range, used instead of a friction profile
    0x2100.10Enable Detent Move Back RW1 = detents on. The detent is defined in the extended force curve, see below.
    DetentsWith 0x2100.10 = 1, detents are defined in the extended force curve (0x20A1 / 0x2113). A detent needs at least three neighbouring points: the middle one has a lower force than its neighbours and marks the detent position. The dip can also consist of two lower points.
    Friction profileAll 18 points must always be filled in, both the positions (0x20A2) and the friction values (0x20A3). As with the extended force curve, points 1 – 9 are the negative side and 10 – 18 the positive side; positions are distances from the centre. Between the points the friction is interpolated linearly; after the last point it stays constant. The profile is only used when the first position point 0x20A2.1 has a value; otherwise the constant friction 0x211D.B applies.
    Quick referenceBreakout force: in the standard layout 0x2113.1 is not amplified by a scale factor above 100 %. End of curve: standard keeps the last slope, extended stays at the last value. Centre feel: 0x6071 sets the centre and minimum force, 0x6067 the width of the soft centre.

    4.3Friction Force Mode (FF mode 2)

    For controls that need the same friction everywhere, such as a helicopter collective. The force curve is inactive: the virtual force is the constant 0x6071 Target Torque (≥ 0) over the whole range. Friction from the friction profile or 0x211D.B is added as in the other modes.

    ObjectNameDescription
    0x2101.1 bit 2Run Profile Mode0 = Friction Force Mode
    0x6071.0Target TorqueFriction force, ≥ 0
    0x2101.1 bit 0Move BackPossible, but rarely useful in this mode

    4.4Constant Force Mode (FF mode 3)

    Applies a constant force in one direction: 0x6071 Target Torque, positive or negative. The axis moves with that force until something holds it. An external controller can build its own force model by reading the position and writing the force continuously. This needs a fast, regular update rate; use the Fast Communication Mode. Delays in the loop are felt at the control.

    ObjectNameDescription
    0x2101.1 bit 1Constant Force1 = Constant Force Mode, only if bit 0 and bit 2 are 0
    0x6071.0Target TorqueForce, signed

    The spring effect is not active in this mode.

    4.5DirectX Mode (FF mode 4)

    Some devices support DirectX force feedback over USB. BRUNNER uses the standard Microsoft implementation, so no driver is needed: games that support DirectInput force feedback control the forces directly. Switch the mode with the USB Config Tool.

    LimitationsDirectX works over USB only. Disable it when the device is used over CAN, for example with CLS2Sim. Synchronisation (MCC) is not available in DirectX mode.
    ObjectNameDescription
    0x2180.1Enable RW1 = DirectX mode. The device restarts after a change.
    0x2180.10Global Force Scale RWOverall force scaling
    0x2180.12Spring Effect Gain RW
    0x2180.13Global Device Damping RW
    0x2180.14Periodic Effect Gain RW
    0x2180.15Constant Force Effect Gain RW
    0x2180.16Damper Effect Gain RW

    4.6FF control word 0x2101.1

    Most mode settings are bits in one 16-bit object. The table collects all bits documented anywhere in this guide.

    BitName1 meansSee
    0Move BackSpring effect on5.8
    1Constant ForceFF mode 3 (only if bits 0 and 2 are 0)4.4
    2Force Linear Up (Run Profile Mode)Use the force curve, FF mode 1 (0 = FF mode 2)4.2
    3One-time TurbulenceOne turbulence oscillation5.10
    4Constant TurbulenceContinuous turbulence5.10
    5Move to positive limitDrive to the positive limit, then shut down4.7
    6Move to negative limitDrive to the negative limit, then shut down4.7
    7, 8Sync ModeBehaviour in synchronisation (combination of both bits)6.3
    9PDO Auto Init FactoryNMT operational after boot-up6
    10Auto StateEnable and home automatically after power-up3.2
    11Set Offset SensorForce sensor zero offset (at power-up if set)4.7
    12Invert Sensor FactoryForce sensor value inverted
    13Start HomingHome when Operation Enabled3.2
    14No InitSkip homing3.2
    15Invert Position FactoryPosition value inverted

    4.7Additional functions

    Move to a limit and shut down

    Before the system is switched off, the axis can drive to a limit. The control is then parked at a defined position while the power is off. Set 0x2101.1 bit 5 (positive limit) or bit 6 (negative limit).

    Force sensor offset

    Sets the force sensor to zero. If bit 11 is set at power-up, the offset runs at every start. This lets the system recover by itself when the sensor has drifted out of its valid range. BRUNNER recommends leaving it on. It has no effect when the force comes from the motor current.

    Hands offThe axis can move while the offset runs. Do not touch the control for about 10 s after start. A disturbed offset leaves a wrong sensor zero; run it again.

    5Force control loop

    The force control loop runs in the drive every 400 µs (2.5 kHz). It passes the measured force through a chain of stages; at the end a speed set-point goes to the velocity regulator.

    Because the loop runs inside the device, an external controller such as CLS2Sim does not need a high update rate in FF modes 1 and 2. In FF mode 3 the external controller closes the loop itself, so the CAN communication must be fast and regular.

    Signal names: AF = actual force, P = position, SC = scale factor, EF = elimination force, FO = force offset, F1 = set force, VF1 = virtual force, V1 – V6 = speed set-point after each stage.

    Which stage works in which FF mode

    Stage1 Profile2 Friction3 Constant4 DirectX
    Stick angle compensation✓✓✓✓
    Trim✓✓✓–
    Scale factor✓–––
    Friction eliminator✓✓✓✓
    Wing airflow✓–––
    Spring effect✓✓––
    Damping✓✓–✓
    Dynamic response✓–––
    Turbulence✓✓✓✓
    Autopilot✓✓✓✓
    Range limit✓✓✓✓
    Synchronisation (MCC)✓✓✓–

    5.1Force sensor selection

    Selects and configures the force sensor. Parameters marked Factory are preset and should not be changed.

    ObjectNameDescription
    0x2107.0FF Torque Sensor Factory0 = external sensor (analogue input 0x2036) · 1 = motor current (0x6077, ‰ of rated torque) · 2 = CAN strain gauge, PDO 16 bit · 3 = CAN strain gauge, PDO 14 bit · 4 = CAN strain gauge, PDO 12 bit · 10 = I²C strain gauge
    0x209D.0Node ID Force Sensor FactoryNode-ID of the CAN strain gauge (sensor types 2 – 4)
    0x209E.0Force Sensor Ext Sync ROValue of the second channel with dual strain gauges (types 2 – 10)
    0x209F.0Force Sensor Ext ROValue of the strain gauge (types 2 – 10)
    0x20A0.0Turn Force Sensor Ext FactorySwaps 0x209E and 0x209F (types 2 – 10)
    0x2170.0Current OffsetConstant current offset (type 1, motor current, only)
    0x211B.0FF Sensor ErrorMaximum force value; above it a force sensor error is raised. Also limits the virtual force to 80 %. Change takes effect after a restart.

    5.2Stick angle compensation

    Compensates the weight of the grip in rotating systems, where the grip's weight adds to the measured force depending on the stick angle. Active when Force Compensation Max is greater than zero.

    ObjectNameDescription
    0x211D.7Force Compensation MaxMaximum compensation, internal units. 0 = off.
    0x211D.8Current Force Compensation ROCompensation value applied now
    0x211D.9Force Compensation Gear Factor1 (default) = maximum compensation at maximum position
    < 1000: compensate positive and negative side
    1001 – 1999: negative side only, factor = value − 1000
    ≥ 2001: positive side only, factor = value − 2000

    5.3Trim

    The trim moves the zero point of the force curve. The curve is evaluated at x = 0x6064 + trim, so the zero point lies at 0x6064 = −trim. The trim is the trim position 0x2116 plus the offset 0x2115. To let an external controller trim smoothly without jitter, large trim changes can be ramped.

    ObjectNameDescription
    0x2116.0Trim Position RWZero point of the force curve
    0x2115.0Trim Offset RWOffset added to the trim position
    0x211C.0Trim Step RWSpeed at which a trim value changed from outside (0x2116) is taken over. 0 = immediately. > 0 = the internal trim moves by this value every 100 µs (10 kHz) until it reaches the new trim position.
    0x2100.9Trim Ramp RW1 = fastest ramp … 20 = slowest ramp. Works together with Trim Step 0x211C.

    5.4Scale factor

    In aircraft with manual controls, the control forces rise with the square of the airspeed: soft near the stall, very stiff near VNE. The scale factor reproduces this by scaling all nine profile points at once, so only one value has to be sent while flying.

    Examples: 100 % = curve as entered · 200 % = double force · 50 % = half force · 20 % = minimum. Above 100 % the breakout force at the centre is not raised. Details, return scale factor and one-sided scaling: 4.2.

    ObjectNameDescription
    0x2114.0Scale Factor RW20 – 1000 %. Active in Profile Force Mode only.
    0x2171.0Reverse Scale Factor RWUsed while the stick returns to the centre, if > 19
    0x211E.0Scale Factor Step RW0 = immediately. > 0 = the scale factor moves by this value every ≈ 40.8 ms.

    5.5Friction eliminator

    Removes small amounts of mechanical friction and a small residual sensor offset. This helps the axis to centre accurately in Profile Force Mode.

    ObjectNameDescription
    0x211D.1Enable Friction Eliminator1 = on
    0x211D.2Friction ValueMaximum elimination force. Too high a value is felt when moving the control.
    0x211D.5Friction TimeTime in ms until the full friction value is reached

    Finding the right friction value

    1. Disable the eliminator.
    2. Move the control in the negative direction, let go, read the force.
    3. Move it in the positive direction, let go, read the force.
    4. Use the larger absolute value as Friction Value. If the effect is noticeable, increase Friction Time or reduce the value.

    5.6Low-speed fade-out (wing airflow)

    Without airflow, on the ground or near the stall, the controls go slack and the elevator hangs forward. Below the scale factor 0x211F two things happen: the force above 0x6071 fades out linearly (flat at 0x6071 at a scale factor of 19, formula in 4.2), and the offset force 0x211A pulls the control. Works in Profile Force Mode only.

    ObjectNameDescription
    0x211F.0Manual Offset Off PosScale factor below which the curve fades out
    0x211A.0Manual Offset ForcePulling force at the lowest scale factor (20 %), falling linearly to 0 at 0x211F

    5.7Profile calculation

    Calculates the set force (F1) from the force profile, the position and the trim, and outputs it as 0x2093 Virtual Force. From the difference between measured force and set force it calculates the speed set-point V1.

    5.8Spring effect (move back)

    With move back on, the axis returns to the zero position by itself. The strength is set with 0x2102 P Move Back: 100 % = no effect, 500 % = strongest spring, standard 200 %. Too high a value can make the system oscillate. Not active in Constant Force Mode.

    ObjectNameDescription
    0x2101.1 bit 0Move Back1 = on
    0x2102.0P Move Back100 – 500 %, default 200 %

    5.9Damping and dynamic response

    When the measured force Fs exceeds the virtual force plus friction, the stick moves:

    if |Fs| > |Fvirtual + friction − 0x2100.B|:
      speed = (|Fs| − |Fvirtual + friction|) × 0x2100.1 / 0x2100.2
      limited to min(0x607F, 0x6080), output 0x60FF
    else: speed = 0

    The direction comes from the sign of the measured force. With speed 0 a single axis holds its position; in master/slave synchronisation it follows the partner. The larger the fraction 0x2100.1 / 0x2100.2, the lower the damping; too little damping makes the system oscillate. 0x2100.2 can be replaced position-dependently by the damping profile: positions in 0x20A5, values in 0x20A6.

    Dynamic response lets the control return to centre faster. Depending on the actual velocity, it reduces the damping denominator. Setting: 0 = off, 1 – 1000 %. Too high a value can cause oscillation.

    ObjectNameDescription
    0x2100.1P Force NumeratorDamping fraction, numerator
    0x2100.2P Force DenominatorDamping fraction, denominator
    0x2100.BForce OffsetPermanent force offset in force sensor units, taken into account in the comparison above
    0x20A5Damping Profile PositionPositions of the damping profile
    0x20A6Damping ProfileDamping values at the positions in 0x20A5; replace 0x2100.2 position-dependently
    0x607F / 0x6080Max profile velocity / max motor speedSpeed limit
    0x60FF.0Target Velocity ROResulting speed set-point
    0x2182.0Dynamic Response0 = off, 1 – 1000 % (FF mode 1 only)
    0x606C.0Actual Velocity ROInput for the dynamic response

    5.10Turbulence generator

    Two independent generators. Generator 1 is meant for low frequencies (turbulence), generator 2 for higher frequencies such as engine vibration. Both use the same waveform.

    ObjectNameDescription
    0x2101.1 bit 3One-time Turbulence1 = one oscillation; its duration is the turbulence time
    0x2101.1 bit 4Constant Turbulence1 = continuous oscillation; its period is the turbulence time
    0x2108.0Turbulence Force, gen. 1Amplitude
    0x2109.0Turbulence Time, gen. 1Period in 1 ms
    0x2099.0Turbulence Force, gen. 2Amplitude
    0x209A.0Turbulence Time, gen. 2Period in 100 µs
    0x2173.0Waveform0 = square (default) · 1 = sine · 2 = triangle · 3 = sawtooth down · 4 = sawtooth up

    5.11Autopilot

    Moves the axis to a target position with a limited force and a maximum speed. If the pilot pushes harder than the autopilot force, the axis gives way and returns as soon as the force falls below the limit. The autopilot does not disconnect by itself; the application (for example CLS2Sim) has to switch it off. While the autopilot runs, most other stages are inactive.

    ObjectNameDescription
    0x2101.4Autopilot Mode0 = disabled · 1 = enabled
    0x2117.0Autopilot PositionTarget position
    0x2118.0Autopilot Position ForceMaximum force
    0x2098.0Autopilot SpeedMaximum speed
    0x6067.0Position WindowThe autopilot stops moving inside this window. Shared with the profile mode.
    0x2100.4Position Mode RampLower value = steeper ramp. Increase if the axis oscillates around the target.

    5.12Range limit

    Keeps the axis inside the software limits and brakes it with the stop ramp. Objects and warnings: see 3.7 Position limits.

    6Synchronisation (MCC)

    For multi-crew cooperation (MCC) training, two axes such as captain's and first officer's aileron are coupled. The two units exchange PDOs directly; no master controller is needed. Synchronisation starts as soon as both devices have finished homing.

    AvailabilitySynchronisation works in FF modes 1, 2 and 3. It is not available in DirectX mode, and it is switched off when the Fast Communication Mode is active, because the PDOs are mapped differently.

    6.1Node-ID assignment

    The node-ID is set in 0x2201. Use these IDs so that CLS2Sim and the synchronisation find the right partner.

    AxisUnit 1 (captain)Unit 2 (first officer)
    Aileron13
    Elevator24
    Rudder56
    Collective78
    Brake left101103
    Brake right102104
    Trim elevator105106
    Trim aileron107108
    Trim rudder109110
    Throttle 1 – 4111 – 114 (shared)
    Speed brake115 (shared)
    Nose wheel116117
    Seat shaker118119

    6.2Old and new synchronisation

    Two methods exist. The better one for each device is configured at the factory.

    Old sync (since 2010)

    + Robust against communication problems
    + Supported by all devices
    − Low or flat force curves can make the axes lag each other
    − Position offset between the axes possible while moving

    Both units: 0x2181.1 = 0

    New sync (since 2023)

    + Accurate also with low forces and flat curves — the main reason for it
    − Not supported by all devices
    − Must be tested on each installation
    − Master and slave must be configured

    Captain 0x2181.1 = 3 (master), first officer = 2 (slave)

    6.3Parameters

    Both units must have the same values, except the destination node-ID and, with new sync, the sync type.

    ObjectNameDescription
    0x2101.2Destination Node-IDNode-ID of the partner axis. Example: captain's aileron (node 1) → 3. Without synchronisation set it to the device's own node-ID.
    0x2181.1Sync Type0 = old sync · 2 = new sync, slave · 3 = new sync, master. Store and restart after changing.
    0x2100.3Velocity Factor (old sync)Higher = slower, softer coupling. Too low causes oscillation. Keep the default.
    0x2181.2Velocity Factor (new sync)As above, for new sync.
    0x2101.7Position Follow Off1 = position is not followed; trim and autopilot stay synchronised. 0 = normal.
    0x2101.1 bit 7, 8Sync ModeBehaviour of the unit in synchronisation, see below
    0x2101.1 bit 9PDO Auto Init FactorySwitches NMT to operational after boot-up (on by default). Do not change it when a force sensor is connected over CAN.

    Sync mode: 0x2101.1 bits 7 and 8

    Bit 7Bit 8Behaviour of the unit
    00Follows the master/slave rules
    10Follows the master/slave rules
    01Follows the partner; its own force input has no effect
    11Unit blocks

    7Fast Communication Mode

    For external real-time controllers that write Target Torque in Constant Force Mode. Position and force are sent on change, up to 1 kHz. This allows own profiles and effects in the controller. FF modes 1 and 2 also work, but are less practical this way.

    0x2091.0 PDO Mapping TypeMappingSynchronisation
    0Standard (default, internal use)on
    1Customer setting 1off
    2Customer setting 2off
    3Customer setting 3off

    Store the value and restart the device to activate the new mapping. Mapping type 0 is not documented; it can be read from the object dictionary.

    Not storedPDO communication and mapping parameters are not saved in non-volatile memory. If you need a different setup, the CANopen master must write it after every boot-up.

    7.1Receive PDOs (to the device)

    PDOComm. objectCOB-IDMapping objectContent
    RPDO10x14000x280 + destination node-ID0x16000x6071 Target Torque (16) · 0x2114 Scale Factor (16) · 0x2101.1 FF control word (16) · 0x2101.3 Update bit (16)
    RPDO20x14010x380 + destination node-ID0x16010x2100.2 P Force Denominator (16) · 0x2116 Trim Position (32)
    RPDO30x14020x53C (reserved)0x1602reserved
    RPDO40x14030x400 + destination node-ID0x16030x2108 Turbulence Force 1 (16) · 0x2109 Turbulence Time 1, ms (16) · 0x2099 Turbulence Force 2 (16) · 0x209A Turbulence Time 2, 100 µs (16)

    7.2Transmit PDOs (from the device)

    PDOComm. objectCOB-IDInhibit time
    standard ×100 µs
    Inhibit time
    dual servo ×500 µs
    Event timer
    standard
    Event timer
    dual servo
    TPDO10x18000x280 + node-ID10 (1 ms, max. 1 kHz)2 (1 ms, max. 1 kHz)100 ms100 ms
    TPDO20x18010x380 + node-ID10 (1 ms, max. 1 kHz)2 (1 ms, max. 1 kHz)200 ms200 ms
    TPDO30x18020xC0000380 (disabled)reserved
    TPDO4, type 10x18030x400 + node-ID0 (off)1000 (500 ms)500 ms1 s
    TPDO4, type 2/30x18030x400 + node-ID100 (10 ms, max. 100 Hz)*not supported500 ms*not supported

    * not supported by all devices

    Mapping objectContent
    0x1A000x2105 Actual Force (16) · 0x6064 Actual Position (32) · 0x6041 Statusword (16)
    0x1A010x606C Actual Velocity (32) · 0x2089.1 or 0x60FD Digital Inputs (32)
    0x1A02reserved
    0x1A03 type 10x2031.1 Drive Temperature (16) · 0x603F Error Code (16) · 0x6079 DC link circuit voltage (32)
    0x1A03 type 20x2031.1 Drive Temperature (16) · 0x603F Error Code (16) · 0x2036 Analogue Input 1 (32)
    0x1A03 type 30x2038 Analogue Input 2 (32) · 0x2036 Analogue Input 1 (32)

    8CANopen and object dictionary

    CANopen is a higher-layer protocol and device profile family on top of CAN. The CAN bus carries the CANopen messages. BRUNNER drives implement CiA 301 (communication profile) and CiA 402 (drives and motion control). Background: CiA CAN knowledge.

    The object dictionary of each CLS device is shown in the CANopen Commander under CAN Device Profile. The device description files (XDD) for integration into other tools are in the Commander installation folder, subfolder CANDeviceProfiles.

    CANopen Commander showing the CAN Device Profile tree of a BRUNNER drive
    CANopen Commander with the object dictionary of a drive

    A complete list of all objects mentioned in this guide is in section 11.

    9Software and tools

    Download all tools from the BRUNNER download area. The software runs on Windows 11, 10, 8.1 and 7.

    9.1CANopen Commander

    Setup and service tool for CANopen devices. It monitors CAN traffic, supports Layer Setting Services (LSS) and sends NMT, SDO and raw CAN messages. Device plugins add functions such as storing and restoring parameters, firmware updates and CiA 402 drive diagnostics. Device profiles can be saved and loaded to set up networks faster.

    It connects to the BRUNNER E2CAN Gateway (Ethernet or driverless USB-HID) or directly to BRUNNER devices with a USB-HID interface. Quick start manual: CANopenCommander_QuickStartManual.pdf in the installation folder.

    9.2CLS2Sim

    Connects BRUNNER CLS devices to flight simulation software. Force by deflection, force increase with speed, trim (with or without BRUNNER electric trim wheels), engine vibration, turbulence, runway effects and stick shaker can be configured for up to 20 axes on the CAN bus. The simulator's autopilot can drive the controls.

    Direct support for Prepar3D, FSX, X-Plane and Microsoft Flight Simulator 2020/2024. Other simulators connect through a TCP/IP or UDP remote interface to read positions, buttons, forces and status, and to set trim, autopilot or force profiles. CLS2Sim online help

    9.3Simux

    Simux connects your simulator with your controllers, bringing input bindings and configurable force effects into one application. Build a common setup, tailor it to individual aircraft, and use aircraft or category assignments to switch profiles automatically.

    Supports Microsoft Flight Simulator 2020 and 2024, X-Plane 11 and 12, and DCS World. Download, quick start and documentation: simux.brunner-innovation.swiss

    9.4USB Config Tool

    Calibrates the axes of USB game controllers and shows buttons, hat switches and axes, similar to the Windows game controller settings. It also switches CLS devices with USB-HID between CLS2Sim and DirectX mode, and selects the grip type of CLS-E and CLS-P joysticks.

    9.5CANopen Tunnel

    Connects CLS devices over Ethernet instead of a continuous CAN cable, so devices can be in different rooms or at different sites. Node-IDs do not have to be coordinated across sites. Error handling copes with higher network delays on long connections. Documentation: CANopenTunnel_UserGuide.pdf in the Doc folder of the download.

    9.6E2CAN IP Config Tool

    Sets the IP address of E2CAN gateways and SMART I/O devices.

    10CAN bus wiring

    CAN is robust against noise, reliable and simple to wire. Its limits are small data packets, moderate data rates and cycle times that can vary. Real installations lose signal margin through cables, connectors, stubs and ground potential differences, so the achievable number of nodes and cable lengths are lower than the theoretical values.

    10.1RJ45 pin assignment

    All BRUNNER CLS devices use RJ45 connectors for CAN. Most devices have two connectors for daisy-chaining.

    PinSignalDescription
    1CAN_HCAN high
    2CAN_LCAN low
    3, 7CAN_GNDGround
    4, 5, 6, 8—Not connected

    10.2Cable and baud rate

    Standard Ethernet cable, category 5 or better. Keep each cable between two devices at 3 m or less, and as short as possible. The CAN baud rate of all BRUNNER CLS devices is fixed at 1 Mbit/s.

    10.3Termination

    A CAN bus needs a 120 Ω resistor between CAN_H and CAN_L at both physical ends of the bus. Without them, signals are reflected at the cable ends and communication errors follow. The ends are the two devices farthest apart along the cable, not in the room.

    Check with a multimeterSwitch all devices off and measure between pin 1 and pin 2 at any free RJ45 socket. About 60 Ω = two terminators, correct. 120 Ω = one is missing. About 40 Ω = three, 30 Ω = four.

    Most installations work with the two standard terminators. Larger systems with more than four devices, such as the MCC installation with gateway in 10.5, need a third terminator; without it the communication does not work reliably. Check the bus with the quality test (10.6) after every change. Contact BRUNNER before fitting a fourth terminator.

    External 120 ohm RJ45 CAN terminator plug
    External 120 Ω RJ45 CAN terminator

    10.4Termination per device

    ArticleDeviceTermination
    GER.1030CLS-P Yokenone, needs external terminator
    GER.1031CLS-P Ruddernone, needs external terminator
    GER.1032CLS-P Cyclicnone, needs external terminator
    GER.1079CLS-B Yokefixed 120 Ω
    GER.1081CLS-P Collective120 Ω, internal switch
    GER.1088E2CAN Gatewaynone, needs external terminator
    GER.1088E2CAN MKII Gateway120 Ω, internal switch
    GER.1089L-Motion 2000 N120 Ω, internal switch
    GER.1097CLS-P Rudder120 Ω, internal switch
    GER.1104CLS-E Yokefixed 120 Ω
    GER.1104CLS-E MKII Yoke120 Ω, object 0x2200
    GER.1130ULC Drive, up to Rev Enone, needs external terminator
    GER.1130ULC Drive, from Rev F120 Ω, object 0x2200
    GER.1137CLS-H Yokefixed 120 Ω
    GER.1141CLS-P Joystick120 Ω, object 0x2200
    GER.1146CLS-P Yoke120 Ω, internal switch
    GER.1147BLDC Drive120 Ω, object 0x2200
    GER.1158CLS-E Rudder120 Ω, object 0x2200
    GER.1160CLS-E Joystick120 Ω, object 0x2200
    GER.1164CLS-B Yoke120 Ω, internal switch
    GER.1168Direct Drive120 Ω, internal switch
    GER.1170CLS-B Rudder120 Ω, internal switch
    GER.1179CLS-E NG Yokefixed 120 Ω
    GER.1219CLS-B Collective120 Ω, internal switch
    GER.1224CLS-P MK2 Cyclic120 Ω, internal switch
    GER.1245L-Motion 200 mm120 Ω, internal switch
    GER.1247CLS-E MK2 Joystick120 Ω, internal switch
    PRT.5245SMART I/O120 Ω, internal switch

    Where a device is listed twice, the higher article number is the newer version. On devices with object 0x2200, the internal terminator is switched on with 1 and off with 0.

    10.5Example installation

    Example MCC installation with CLS-P rudders, collectives and cyclics, E2CAN MKII gateway and terminations
    MCC installation with gateway. The terminations marked in the drawing are required.

    In this example the E2CAN gateway also needs its termination switched on.

    The two CAN connectors of the E2CAN gateway are looped through (daisy chain); the gateway does not split the bus into two segments. This installation therefore needs three terminators.

    10.6CAN bus quality test

    1. CLS2Sim communication statistics. Connect with CLS2Sim and open the communication statistics with the Details button. Timeouts/s and Timeouts tot should stay at 0. A few timeouts per hour are acceptable. If a value keeps rising, check termination and cable lengths. The bus load should be below 50 %, and no CAN bus errors should be active.
      CLS2Sim communication statistics window
    2. Reset the gateway statistics. Click the IP address in CLS2Sim, or enter it in a browser, to open the web page of the E2CAN Gateway MK2 or SMART I/O. Under Commands, apply Reset Stats.
      E2CAN Gateway MK2 web page, Commands
    3. Check the CAN interface counters. Open CAN Interface. All counters should stay at zero, except Tx FIFO Level Max and Rx FIFO Level Max. If a counter rises, check termination and cable lengths.
      E2CAN Gateway MK2 web page, CAN interface statistics

    11Object index

    All objects in this guide, sorted by index. Use the filter or the search at the left.

    ObjectNameSection
    0x1400 – 0x1403RPDO communication parameters7.1
    0x1600 – 0x1603RPDO mapping7.1
    0x1800 – 0x1803TPDO communication parameters7.2
    0x1A000x2105 Actual Force (16) · 0x6064 Actual Position (32) · 0x6041 Statusword (16)7.2
    0x1A00 – 0x1A03TPDO mapping7.2
    0x1A010x606C Actual Velocity (32) · 0x2089.1 or 0x60FD Digital Inputs (32)7.2
    0x1A02reserved7.2
    0x1A03 type 10x2031.1 Drive Temperature (16) · 0x603F Error Code (16) · 0x6079 DC link circuit voltage (32)7.2
    0x1A03 type 20x2031.1 Drive Temperature (16) · 0x603F Error Code (16) · 0x2036 Analogue Input 1 (32)7.2
    0x1A03 type 30x2038 Analogue Input 2 (32) · 0x2036 Analogue Input 1 (32)7.2
    0x2031.1Drive Temperature7.2
    0x2036.0Analogue Input 17.2
    0x2038.0Analogue Input 27.2
    0x2057.0Homing Delay3.5
    0x2058.0Homing Current Limit3.5
    0x2059.0Last Homing Error3.6
    0x205A.1Homing Option3.5
    0x205A.2Homing Option KP3.5
    0x2089.1Digital Inputs7.2
    0x2091.0PDO Mapping Type7
    0x2093.0Virtual Force4.2, 5.7
    0x2098.0Autopilot Speed5.11
    0x2099.0Turbulence Force, gen. 25.10
    0x209A.0Turbulence Time, gen. 25.10
    0x209C.0Software negative limit3.7
    0x209C.0Neg Limit4.2
    0x209D.0Node ID Force Sensor5.1
    0x209E.0Force Sensor Ext Sync5.1
    0x209F.0Force Sensor Ext5.1
    0x20A0.0Turn Force Sensor Ext5.1
    0x20A1.1 – .12Force Profile Position4.2
    0x20A2.1 – .12Friction Profile Position4.2
    0x20A3.1 – .12Friction Profile4.2
    0x20A5Damping Profile Position5.9
    0x20A6Damping Profile5.9
    0x2100.1P Force Numerator5.9
    0x2100.2P Force Denominator5.9
    0x2100.3Velocity Factor (old sync)6.3
    0x2100.4Position Mode Ramp5.11
    0x2100.8Soft Limit Stop Ramp3.7
    0x2100.9Trim Ramp5.3
    0x2100.BForce Offset5.9
    0x2100.CSelect Profile Mode3.7
    0x2100.CProfile Mode4.2
    0x2100.ESubindex in hexadecimal: E = 14, 10 = 161
    0x2100.E bit 1Init Always3.2
    0x2100.E bit 2Disable Limits3.7
    0x2100.FOne-sided scaling4.2
    0x2100.FOne-sided Scaling4.2
    0x2100.10Enable Detent Move Back4.2
    0x2101.1 bit 0Move Back4.2, 4.3, 5.8
    0x2101.1 bit 1Constant Force4.4
    0x2101.1 bit 2Force Linear Up (Run Profile Mode)4.2
    0x2101.1 bit 2Run Profile Mode4.3
    0x2101.1 bit 3One-time Turbulence5.10
    0x2101.1 bit 4Constant Turbulence5.10
    0x2101.1 bit 7, 8Sync Mode6.3
    0x2101.1 bit 9PDO Auto Init6.3
    0x2101.1 bit 10Auto State3.2
    0x2101.1 bit 13Single bit in a bit-field object, counted from bit 0 (least significant)1
    0x2101.1 bit 13Start Homing3.2
    0x2101.1 bit 14No Init3.2
    0x2101.1 bit 15Invert Position4.2
    0x2101.2Destination Node-ID6.3
    0x2101.4Autopilot Mode5.11
    0x2101.7Position Follow Off6.3
    0x2102.0P Move Back5.8
    0x2107.0FF Torque Sensor5.1
    0x2108.0Turbulence Force, gen. 15.10
    0x2109.0Turbulence Time, gen. 15.10
    0x2113.1 – .12Force Profile4.2
    0x2114.0Object index 0x2114, subindex 01
    0x2114.0Scale Factor4.2, 4.2, 5.4
    0x2115.0Trim Offset5.3
    0x2116.0Trim Position5.3
    0x2117.0Autopilot Position5.11
    0x2118.0Autopilot Position Force5.11
    0x2119.0Software positive limit3.7
    0x2119.0Pos Limit4.2
    0x211A.0Manual Offset Force5.6
    0x211B.0Sensor Error4.2
    0x211B.0FF Sensor Error5.1
    0x211C.0Trim Step5.3
    0x211D.1Enable Friction Eliminator5.5
    0x211D.2Friction Value5.5
    0x211D.5Friction Time5.5
    0x211D.7Force Compensation Max5.2
    0x211D.8Current Force Compensation5.2
    0x211D.9Force Compensation Gear Factor5.2
    0x211D.BConstant Friction Value4.2
    0x211E.0Scale Factor Step4.2, 4.2, 5.4
    0x211F.0Manual Offset Off Pos4.2, 5.6
    0x2170.0Current Offset5.1
    0x2171.0Reverse Scale Factor4.2, 4.2, 5.4
    0x2173.0Waveform5.10
    0x2180.1Enable4.5
    0x2180.10Global Force Scale4.5
    0x2180.12Spring Effect Gain4.5
    0x2180.13Global Device Damping4.5
    0x2180.14Periodic Effect Gain4.5
    0x2180.15Constant Force Effect Gain4.5
    0x2180.16Damper Effect Gain4.5
    0x2181.1Sync Type6.3
    0x2181.2Velocity Factor (new sync)6.3
    0x2182.0Dynamic Response5.9
    0x2200.0CAN termination on/off10.4
    0x2201.0Node-ID6.1
    0x603F.0Error Code7.2
    0x6041 bit 12Homing attained3.6
    0x6041 bit 13Homing error3.6
    0x6060.0Modes of Operation2
    0x6067.0Position Window4.2, 5.11
    0x606C.0Actual Velocity5.9
    0x6071.0Target Torque4.2, 4.3, 4.4
    0x6079.0DC link circuit voltage7.2
    0x607C.0Home Offset3.5
    0x607D.1 / .2Min / Max Position Limit3.5
    0x607F / 0x6080Max profile velocity / max motor speed5.9
    0x6098.0Homing Method3.5
    0x6099.1Homing Speed3.5
    0x60FD.0Digital Inputs7.2
    0x60FF.0Target Velocity5.9

    12Glossary and revisions

    TermMeaning
    CLSControl loading system: a control (stick, yoke, rudder…) with active force feedback
    HomingReferencing the position after power-up (also called initialisation)
    FF modeOne of the four force feedback modes inside CiA 402 mode −1
    Trim pointZero position of the force profile
    MCCMulti-crew cooperation: two synchronised sets of controls
    PDO / SDOProcess data object (fast, cyclic) / service data object (parameter access)
    NMTNetwork management: pre-operational, operational, stopped
    Strain gauge (DMS)Force sensor based on a Dehnungsmessstreifen
    PMSMPermanent magnet synchronous motor
    VersionDateChanges
    1.227.12.2024Last draw.io version
    2.005.10.2026New HTML edition: searchable, responsive, print-ready. Homing rewritten with all methods and interactive demonstration. Consolidated bit map of 0x2101.1, object index, corrected cross-references and PDO tables, device list sorted, termination check added.